Hi Ray, it works perfectly.
Thank you very much!
Em seg., 13 de jun. de 2022 às 19:31, Ray Daniel Zimmerman
escreveu:
> When running a power flow the voltage at swing and PV buses is controlled
> by the VG column of the corresponding generator in the gen matrix, not by
> the VM column in bus.
When running a power flow the voltage at swing and PV buses is controlled by
the VG column of the corresponding generator in the gen matrix, not by the VM
column in bus. Setting the corresponding mpc.gen(slack_gen_index, VG) to the
desired value in your loop should accomplish what you are
Hi, my name is João Amaral. I am a researcher from the Alternative Energy
Laboratory (LAFAE) in COPPE/UFRJ, Brazil.
We are working in the modelling of a Wind Farm using Matpower in Matlab and
we are trying to compare field measures with the results from the program.
For this we are using a "For