Re: [OpenIndiana-discuss] building a new box soon- HDD concerns and recommendations for virtual serving

2013-04-19 Thread Carl Brewer
On 17/04/2013 8:25 PM, Aneurin Price wrote: On 17 April 2013 03:53, Carl Brewer wrote: Further to my original post, I have a new (desktop, I know ... but I am on a tight budget) Intel MB with an i5-3750 CPU and 32 GB of desktop RAM. Booting the 151a7 live DVD shows that it thinks it's a 32 bit

Re: [OpenIndiana-discuss] vdev reliability was: Recommendations for fast storage

2013-04-19 Thread Richard Elling
[catching up... comment below] On Apr 18, 2013, at 2:03 PM, Timothy Coalson wrote: > On Thu, Apr 18, 2013 at 10:24 AM, Sebastian Gabler > wrote: > >> Am 18.04.2013 16:28, schrieb >> openindiana-discuss-request@**openindiana.org >> : >> >>> Message: 1 >>> Date: Thu, 18 Apr 2013 12:17:47 +

Re: [OpenIndiana-discuss] vdev reliability was: Recommendations for fast storage

2013-04-19 Thread Richard Elling
[catching up...] On Apr 19, 2013, at 6:14 AM, Sebastian Gabler wrote: > Am 19.04.2013 11:22, schrieb openindiana-discuss-requ...@openindiana.org: > > Message: 1 > Date: Thu, 18 Apr 2013 16:03:32 -0500 > From: Timothy Coalson > To: Discussion list for OpenIndiana > > Subject: Re: [OpenInd

Re: [OpenIndiana-discuss] vdev reliability was: Recommendations for fast storage

2013-04-19 Thread Timothy Coalson
On Fri, Apr 19, 2013 at 8:14 AM, Sebastian Gabler wrote: > > On Thu, Apr 18, 2013 at 10:24 AM, Sebastian Gabler >wrote: > > > One of Elling's posts cited by another poster did >> take that into account, but the graphs don't load due to url changes (and >> they seem to have the wrong MIME type wit

Re: [OpenIndiana-discuss] zpool vdev membership misreported

2013-04-19 Thread Jim Klimov
On 2013-04-19 11:20, Justin Warwick wrote: I broke the mirror on the "media" pool (i can't remember whey I did that). Since that time I have been getting that message which seems to mean somehow the disk is halfway stuck in the mirror. Agreeing with George's answer, I'd like to inquire: how did

Re: [OpenIndiana-discuss] zpool vdev membership misreported

2013-04-19 Thread George Wilson
Justin, More than likely c3d1 contain a label from an old pool. If you run 'zdb -l /dev/dsk/c3d1s0' you should be able to if one exists. If does contain information for an old pool then using the '-f' option when attaching will solve your problem and relabel the device with the new pool infor

Re: [OpenIndiana-discuss] vdev reliability was: Recommendations for fast storage

2013-04-19 Thread Sebastian Gabler
Am 19.04.2013 11:22, schrieb openindiana-discuss-requ...@openindiana.org: Message: 1 Date: Thu, 18 Apr 2013 16:03:32 -0500 From: Timothy Coalson To: Discussion list for OpenIndiana Subject: Re: [OpenIndiana-discuss] vdev reliability was: Recommendations for fast storage Message-I

Re: [OpenIndiana-discuss] IPNAT redirection.

2013-04-19 Thread Jonathan Adams
I kinda assumed that the packets would have been translated to be from the machine on the firewall ... it was only after snooping from the firewall that I noticed the originator ... I'm going to have to "delegate" because I don't trust the windows server to know anything about the outside world.

Re: [OpenIndiana-discuss] IPNAT redirection.

2013-04-19 Thread Gary Gendel
We've all been there. :( On 04/19/2013 08:08 AM, Jonathan Adams wrote: ignore me, i'm just being stupid! on the accelerated host I needed to add the route to the external server :( On 19 April 2013 12:58, Jonathan Adams wrote: On 19 April 2013 11:45, Gary Gendel wrote: Jon, I redirect

Re: [OpenIndiana-discuss] IPNAT redirection.

2013-04-19 Thread Jonathan Adams
ignore me, i'm just being stupid! on the accelerated host I needed to add the route to the external server :( On 19 April 2013 12:58, Jonathan Adams wrote: > On 19 April 2013 11:45, Gary Gendel wrote: > >> Jon, >> >> I redirect ports fine using nat. I'm trying to understand what's >> differe

Re: [OpenIndiana-discuss] IPNAT redirection.

2013-04-19 Thread Jonathan Adams
On 19 April 2013 11:45, Gary Gendel wrote: > Jon, > > I redirect ports fine using nat. I'm trying to understand what's > different between your and my setup. For example in my ipnat.conf file I > have: > > rdr bge0 0.0.0.0/0 port 2022 -> 10.101.1.9 port 22 tcp/udp > > Where bge0 is my external

Re: [OpenIndiana-discuss] IPNAT redirection.

2013-04-19 Thread Gary Gendel
Jon, I redirect ports fine using nat. I'm trying to understand what's different between your and my setup. For example in my ipnat.conf file I have: rdr bge0 0.0.0.0/0 port 2022 -> 10.101.1.9 port 22 tcp/udp Where bge0 is my external nic (bge1 is my internal nic). BTW, I use 0.0.0.0/0 so

Re: [OpenIndiana-discuss] IPNAT redirection.

2013-04-19 Thread Jonathan Adams
more specific addresses to forward: root@oldfluffy:/etc/ipf# ipnat -l List of active MAP/Redirect filters: rdr iprb0 n.n.62.35/32 port 143 -> 192.168.0.12 port 143 tcp rdr bge0 192.168.0.65/32 port 143 -> 192.168.0.12 port 143 tcp List of active sessions: RDR 192.168.0.12 143 <- ->n.n.62.35

Re: [OpenIndiana-discuss] IPNAT redirection.

2013-04-19 Thread Jonathan Adams
Actually in the real system I am trying to forward a port from an external address (on the internet, the address I hid) to an internal RDP server (port 3389 tcp) ... but for testing I forwarded to an internal IMAP server iprb0 is the external interface, bge0 is the internal. I added bge0 to see i

[OpenIndiana-discuss] zpool vdev membership misreported

2013-04-19 Thread Justin Warwick
jrw@valinor:~$ pfexec zpool attach media c2d1 c3d1 invalid vdev specification use '-f' to override the following errors: /dev/dsk/c3d1s0 is part of active ZFS pool rpool. Please see zpool(1M). Yet I do not see c3d1 in zpool status. Initially I had 4 disks total, all Seagate SATA drives, two separ