Re: [Owfs-developers] 1-wire counter substitute

2011-09-08 Thread Jan Kandziora
Am Freitag, 9. September 2011, 02:00:28 schrieb p4trykx: > > But this is a quote form datasheet. Page 5 table with pin description > http://datasheets.maxim-ic.com/en/ds/DS2408.pdf > > ...When configured as STRB, an output strobe will occur after a PIO write > (see Channel-Access Write command) >

Re: [Owfs-developers] 1-wire counter substitute

2011-09-08 Thread p4trykx
Dnia 21-08-2011 o 00:10:21 Jan Kandziora napisał(a): (Other useful chips like the DS2409 are discontinued, too. I think it is time to think about home-brewn replacement parts using AVR or PIC controllers.) There is a project to replace the counter and the switch with AVR but it only comp

Re: [Owfs-developers] 1-wire counter substitute

2011-08-20 Thread Alex Shepherd
Hi p4trykx, > As the 1-wire counter is discontinued I tried to make my own counter from > ds2408 and 8-bit counter with bit output 74hc590. > It all stared when my energy supplier changed the energy meter to > electronic one with blinking led. It pulses 1200 times per kWh. > I read those pulses wi

Re: [Owfs-developers] 1-wire counter substitute

2011-08-20 Thread Jan Kandziora
Am Samstag, 20. August 2011, 22:59:35 schrieb p4trykx: > Hello > As the 1-wire counter is discontinued I tried to make my own counter from > ds2408 and 8-bit counter with bit output 74hc590. > The DS2408 is discontinued, too. I think the chips will be available a while through brokers, though the

Re: [Owfs-developers] 1-wire counter substitute

2011-08-20 Thread p4trykx
Dnia 20-08-2011 o 23:24:21 Mark Richards napisał(a): According to the counter.png, the emitter and collector of Q1 are both tied to ground.> I am not certain how this will work wired as such. Sorry. I forgot to delete GND connection on schematic. -- p4trykx<> 1wire_licznik fototranzys

Re: [Owfs-developers] 1-wire counter substitute

2011-08-20 Thread Mark Richards
On 8/20/2011 16:59, p4trykx wrote: Hello As the 1-wire counter is discontinued I tried to make my own counter from ds2408 and 8-bit counter with bit output 74hc590. It all stared when my energy supplier changed the energy meter to electronic one with blinking led. It pulses 1200 times per kWh.

[Owfs-developers] 1-wire counter substitute

2011-08-20 Thread p4trykx
Hello As the 1-wire counter is discontinued I tried to make my own counter from ds2408 and 8-bit counter with bit output 74hc590. It all stared when my energy supplier changed the energy meter to electronic one with blinking led. It pulses 1200 times per kWh. I read those pulses with phototran