[powernet] RE: Dosimeter Pre-Alarms

2016-04-28 Thread Thomson, Raymond W.
Columbia does not use pre-alarm function. Workers are to monitor their accumulated dose at least every 15 minutes and exit the area at 80% of the dose alarm set point. Ray Thomson Health Physics Craft Supervisor Columbia Generating Station rwthom...@energy-northwest.com Office, 509-377-8273

[powernet] RE: [EXTERNAL] [powernet] DMC2000GN

2016-04-28 Thread Vickers, Glen:(GenCo-Nuc)
I’ve done testing with v.1.11.03. Glen Vickers, CHP Exelon Corp RP Technical Lead 815-216-2723 (work/cell) From: Bradley A Krupp [mailto:kru...@dteenergy.com] Sent: Thursday, April 28, 2016 7:53 AM To: Powernet@hpspowernet.org Cc: Mark T Smith; Vincent J Petriano Subject: [EXTERNAL] [powernet]

[powernet] DMC2000GN

2016-04-28 Thread Bradley A Krupp
Fermi would like to talk with anyone who has used the DMC2000GN with version 1.08.04 of Sentinel. Please provide contact information. Thanks in advance for your assistance. Brad Krupp

[powernet] RE: Dosimeter Pre-Alarms

2016-04-28 Thread Scherman, John
DCPP uses pre-alarms or alerts. We use DMC3000 dosimeters and Sentinel v1.11 John Scherman Radiation Protection Technology Foreman Diablo Canyon Power Plant 805.545.4417 DCPP Omnicast VMS Support Email Omnicast Support From:

Re: [powernet] RE: Dosimeter Pre-Alarms

2016-04-28 Thread Bob Simmons (Generation - 3)
Dominion does not use the pre-alarms. Sent from my iPhone On Apr 27, 2016, at 5:38 PM, Noble, Douglas L > wrote: Davis-Besse does not. Alignment with Duke, Exelon. From: Creamer, Charles E [mailto:cecrea...@tva.gov] Sent:

Re: [powernet] Dosimeter Pre-Alarms

2016-04-28 Thread Benjy P Bertossi
Fermi does not use ED pre-alarm function. Benjy Bertossi Fermi2 - RP Supervisor 734-586-1072 or 4935 bertos...@dteenergy.com -"Creamer, Charles E" wrote: - To: "'powernet@hpspowernet.org'" From: "Creamer, Charles E"