At Davis-Besse small volume oil samples from equipment within the RCA are sent
to a licensed laboratory for analysis due to inability to attain environmental
lower limits of detection.
Health Physics Position Statement 189 discusses parameters which if met, would
make it permissible to send
Davis-Besse does not.
From: Powernet On Behalf Of John Sukosky via
Powernet
Sent: Thursday, May 09, 2019 9:10 AM
To: powernet@hpspowernet.org
Cc: John Sukosky ; Selma Spratley
; Beth Hilt
Subject: [EXTERNAL] [Powernet] Advanced Rad Worker Monitoring, Release &
Transfer of Rad Material From
Are you referring to functional tests or source checks ?
Sent from my iPhone
On May 1, 2019, at 1:07 PM, Paciello, Lara R via Powernet
mailto:powernet@hpspowernet.org>> wrote:
Hello,
How often do you perform operational tests on your High Range Monitors? Does
anyone have a reference for
No seals used here
From: Powernet On Behalf Of Holmes, Stephen
J:(GenCo-Nuc) via Powernet
Sent: Tuesday, April 09, 2019 4:04 PM
To: powernet@hpspowernet.org
Cc: Holmes, Stephen J:(GenCo-Nuc)
Subject: Re: [Powernet] [EXTERNAL] RP field instrument tamper seals
No, we do not require tamper seals
1. I
2. Yes to both. I/C technicians are trained and qualified to check out and
use calibration sources. RP escorts and controls access to areas where the
higher range sources are used i.e., area monitors.
Sent from my iPad
On Jan 28, 2019, at 12:38 PM, Holmes, Stephen J:(GenCo-Nuc) via
Got it!
-Original Message-
From: Powernet On Behalf Of Linda Sewell via
Powernet
Sent: Thursday, September 27, 2018 10:21 AM
To: powernet@hpspowernet.org
Cc: Linda Sewell
Subject: [EXTERNAL] [Powernet] Test Post
Hi All,
I haven’t seen any posts for awhile. I am just verifying
Davis-Besse has not.
Sent from my iPad
On Jul 25, 2018, at 9:29 AM, FOGLE, RICHARD R via Powernet
mailto:powernet@hpspowernet.org>> wrote:
V.C. Summer would like to know if anyone has worked in their Reactor Building
at 100% power utilizing Delta Suits/Bubble Suits?
Thanks,
Ryan
Davis-Besse uses a 10% bias. The differences between online and outage are
significant. On-line 35-40%; Outage 8%.
Sent from my iPad
On Jun 28, 2018, at 11:12 AM, James P Stewart via Powernet
mailto:powernet@hpspowernet.org>> wrote:
Fermi has a 10% bias on SRD (DMC2000/3000). We see
Received
Sent from my iPhone
> On Jun 21, 2018, at 12:21 AM, Linda Sewell via Powernet
> wrote:
>
> Please let me know if you got this message. If it’s obvious that it’s
> working after a few replies there is no need to acknowledge.
>
> Thanks,
>
> Linda Sewell
> Powernet Moderator
>
For BWRs, can I get a quick benchmark on the number of temporary drip catches
installed at your station?
Thanks
Sent from my iPad
--
The information contained in this message is intended only for the personal and
Requesting if someone uses a company other than Battelle for tld spiked sample
program?
Douglas L Noble
Radiation Protection Manager
Davis-Besse Nuclear Power Station
5501 North State Route 2
Oak Harbor Ohio 43449
419.321.7780 (work)
419.304.0068 (cell)
11 matches