Re: [Powernet] DLR vs SRD Comparison

2019-09-24 Thread Paciello, Lara R via Powernet
FENOC uses [cid:image002.png@01D572C8.F63769B0] Dr. Lara Renz Paciello, CHP Radiation Protection – Dosimetry Laboratory Beaver Valley Power Station 724-682-5857 From: Powernet On Behalf Of Robinson, Brent via Powernet Sent: Tuesday, September 24, 2019 10:00 AM To: powernet@hpspowernet.org Cc: R

Re: [Powernet] [EXTERNAL] Frequency of Compensatory Sampling for OOS Effluent Radiation Monitors

2019-07-11 Thread Paciello, Lara R via Powernet
We collect once per 8 hours so we don't miss a 12 hour requirement. Dr. Lara Renz Paciello, CHP Radiation Protection - Dosimetry Laboratory Beaver Valley Power Station 724-682-5857 From: Powernet On Behalf Of Barber, Jerry M via Powernet Sent: Wednesday, July 10, 2019 5:35 PM To: powernet@hpspo

Re: [Powernet] Whole Body Count/PCE Benchmark

2019-07-10 Thread Paciello, Lara R via Powernet
1. What does your site consider a positive WBC? BFN currently considers a bioassay result (in vitro or diagnostic in vivo) that indicates the presence of licensed material in a quantity greater than minimum detectable activity (MDA) for the counter being used as positive. SAME 1. What le

Re: [Powernet] surveys following medical exposure to radiopharmaceutical

2019-05-16 Thread Paciello, Lara R via Powernet
Beaver Valley is the same as North Anna's response, except we don't let them in the RCA at all. Dr. Lara Renz Paciello, CHP Radiation Protection - Dosimetry Laboratory Beaver Valley Power Station 724-682-5857 From: Powernet On Behalf Of BJ Thompson via Powernet Sent: Wednesday, May 15, 2019 5:

Re: [Powernet] [EXTERNAL] High Range Noble Gas Monitors

2019-05-01 Thread Paciello, Lara R via Powernet
: [Powernet] [EXTERNAL] High Range Noble Gas Monitors Are you referring to functional tests or source checks ? Sent from my iPhone On May 1, 2019, at 1:07 PM, Paciello, Lara R via Powernet mailto:powernet@hpspowernet.org>> wrote: Hello, How often do you perform operational tests on your High

[Powernet] High Range Noble Gas Monitors

2019-05-01 Thread Paciello, Lara R via Powernet
Hello, How often do you perform operational tests on your High Range Monitors? Does anyone have a reference for where this requirement would come from? Thanks, Dr. Lara Renz Paciello, CHP Radiation Protection - Dosimetry Laboratory Beaver Valley Power Station 724-682-5857

Re: [Powernet] Release of Oil Samples

2019-04-03 Thread Paciello, Lara R via Powernet
BVPS had the same problem a number of years ago. We used to take some kind of exemption, but that was no longer acceptable to our management (not sure the exact details because it was before my time). We now just ship as rad material to a licensed vendor. Dr. Lara Renz Paciello, CHP Radiatio

Re: [Powernet] Quick Hit Benchmark – Area TLD/OSL Monitoring

2019-03-25 Thread Paciello, Lara R via Powernet
>From Beaver Valley - 1. Aligned with our personnel monitoring periods, which are roughly 3-4 months depending on outage schedules (we are a two unit site). 2. We use LiF TLDs for onsite area monitoring. These are NOT REMP area TLDs – just to clarify. 3. We have increased over the year

Re: [Powernet] Peroxide add to cavity

2019-03-14 Thread Paciello, Lara R via Powernet
Not sure if the concentrations will be the same, but we performed this by adding 5 gallons to the cavity prior to drain down and saw no effect on Decon effort. May not be worth the effort, but also had no negative effects. Dr. Lara Renz Paciello, CHP Radiation Protection - Dosimetry Laborator

Re: [Powernet] Process and Area Radiation Monitors

2019-03-13 Thread Paciello, Lara R via Powernet
Response from Beaver Valley - almost the same as Davis Besse: 1. Who calibrates and repairs the installed plant process monitors (e.g., air and liquid monitors)? Maintenance I&C, with support from RP 1. Who calibrates and repairs the installed plant area radiation monitors? Mainten

Re: [Powernet] Benchmark - WBC Check Source

2019-01-09 Thread Paciello, Lara R via Powernet
1. What WBC system are you using? Mirion/Canberra Accuscan-II with dual HPGe detectors and also was have a Mirion/Canberra Fastscan with dual NaI detectors. We use APEX InVivo Software (recent upgrade). 1. What nuclides/peaks are you using to perform your routine QC checks? Cs-137/Co-60 s

Re: [Powernet] Biological Sample Collection Snapshot

2018-12-03 Thread Paciello, Lara R via Powernet
Same here. Dr. Lara Renz Paciello, CHP Radiation Protection - Dosimetry Laboratory Beaver Valley Power Station 724-682-5857 From: Powernet On Behalf Of McCarthy, John:(GenCo-Nuc) via Powernet Sent: Wednesday, November 14, 2018 8:03 AM To: powernet@hpspowernet.org Cc: McCarthy, John:(GenCo-Nuc)

Re: [Powernet] Suspension of Whole Body Counts...

2018-11-30 Thread Paciello, Lara R via Powernet
At FENOC, we take credit for our SPM-906 gamma portal monitors for internal monitoring, which negates the need to whole body count on a routine basis. New employees and visitors, etc., are required to step through a portal monitor before receiving a TLD. End of employment monitoring happens wh

Re: [Powernet] Quick Benchmarking on ED's

2018-11-01 Thread Paciello, Lara R via Powernet
Beaver Valley uses DMC3000s - we transitioned last year. I believe all of FENOC (DB and Perry) is transitioning now, although I do not have a specific status. We just received the test tool for the battery consumption issue and will be starting testing today. Thank you for providing data. Tha

Re: [Powernet] Radioactive Release Performance Criteria question

2018-08-14 Thread Paciello, Lara R via Powernet
No, we performed our NFPA 805 analysis using Dry Active Wastes, such as contaminated materials stored in a seavan in the yard area. For wet wastes, or liquids, you may want to consider requiring administrative spill prevention techniques to contain the waste. I believe we implemented use of f

Re: [Powernet] Mirion DMC3000 Electronic Dosimeter Battery Benchmark

2018-07-26 Thread Paciello, Lara R via Powernet
#1. Procell Industrial by Duracell. #2. Manufacture rates battery life for 1 year ( 1 year is manufacture recommended calibration frequency ). We have no problem with battery life, but then by procedure batteries are changed prior to calibration every 6 months. #3. Transmitters are not

[Powernet] add email

2018-07-10 Thread Paciello, Lara R via Powernet
Please add me to your list. I used to be part of this group, but my name changed due to marriage and I believe my email fell off. lpacie...@firstenergycorp.com Thanks, Dr. Lara Renz Paciello, CHP Radiation Protection - Dosimetry Laboratory Beaver Valley Power Station 724-682-5857 --

[Powernet] Question about a Declared Pregnant Worker

2018-07-10 Thread Paciello, Lara R via Powernet
Hello, I am wondering if anyone has had any experience with a Control Room Licensed Operator who declares pregnancy. At First Energy, we administratively control DPW dose to < 50 mrem/month. My concern is whether or not a licensed individual would risk her limit in the event of a plant emerge

[powernet] RE: *EXTERNAL* [powernet] Quick Whole Body Counter Performance Benchmark

2017-04-26 Thread Paciello, Lara R
1. What whole body counters do you use? Canberra AccuscanII and Canberra Fastscan 2. What is your calibration frequency for whole body counters? Annual 3. What is your frequency for performing a source check on the whole body counters? Daily for the Accuscan (no holidays or

[powernet] RE: *EXTERNAL* [powernet] Benchmark Response Request Question #2 of 2

2017-02-27 Thread Paciello, Lara R
1. Do you use neutron electron dosimetry? We have, but not always. 2. If yes, what model / manufacturer? DMC2000GN Mirion Electronic Alarming Dosimeters (EADs) 3. Where / when is it used? We recently used them for our dry cask campaigns. In order to do so, we had to expose the EADs to o

[powernet] RE: *EXTERNAL* [powernet] Benchmark Response Request Question #1 of 2

2017-02-27 Thread Paciello, Lara R
1. Have you changed your DLR personnel monitoring period (i.e. quarterly to 6 months, 6 months to annual)? No. We generally have a monitoring period change approximately every 3-4 months, depending on our outage schedule. 2. Did you experience a change in the number of individuals with do

[powernet] RE: *EXTERNAL* [powernet] RE: Quick Whole Body Counter Benchmark

2017-02-23 Thread Paciello, Lara R
At Beaver Valley, we also have: 1 Canberra Accuscan with a germanium detector 1 Canberra Fastscan with a sodium iodide detector Dr. Lara Renz Paciello, CHP Radiation Protection - Dosimetry Laboratory Beaver Valley Power Station 724-682-5857 From: Holmes, Stephen J:(GenCo-Nuc) [mailto:stephen.hol