Re: [RE-wrenches] Enphase Wire Management

2013-04-13 Thread Andrew Truitt
Aaron - Zep makes a bracket for supporting Enphase connectors which is quite robust: http://www.zepsolar.com/images/files/components/pdf/Enphase-Connector-Bracket-RevD-Writing_CLI.pdf Of course it is intended for use with Zep compatible modules. - Andrew Sent from my iPhone On Apr 12,

[RE-wrenches] outback fx series inverters

2013-04-13 Thread Todd Cory
wrenches... put on our tin foil hats... i have a customer who claims the emf from their grid tied gvfx3648 is making them sick. does anyone know the switching frequency of the inverter and has anyone else reported this? also any ideas on how to

Re: [RE-wrenches] outback fx series inverters

2013-04-13 Thread Chris Mason
You can't mitigate someone's imagination. EMF is all around, imagine what they would be exposed to under power lines. But unless they have an extremely high level of iron in their blood, they are not ferrous and will not be affected. On Sat, Apr 13, 2013 at 3:17 PM, Todd Cory

Re: [RE-wrenches] outback fx series inverters

2013-04-13 Thread Randy Brooks
Have you used a gaus meter (http://www.amazon.com/Gen-El-Gauss-Master/dp/B0004IR6J6/ref=sr_1_2?ie=UTF8qid=1365882645sr=8-2keywords=gaus+meter) to measure the EMF near the inverters and other places? Might put it in perspective. Randy On Apr 13, 2013, at 12:17 PM, Todd Cory

Re: [RE-wrenches] outback fx series inverters

2013-04-13 Thread toddcory
the customer had some guy come in with 'a meter'. there was no mention of frequency or scale for the ranges listed below. and of course... the man with the meter also sells the 'filters' which help the problem he finds - sigh. here is the pertinent paragraph in her letter to me: As you know,

Re: [RE-wrenches] outback fx series inverters

2013-04-13 Thread Chris Daum
I don't knowI have perhaps three customers, over the past ~20 years, who claim to be 'allergic to electricity', for lack of a better term. As you can imagine, existing in our current society is actually painful for them. They've all bought (for example) propane 'fridges since they use no

Re: [RE-wrenches] outback fx series inverters

2013-04-13 Thread Roy Butler
Sounds an awful lot like "Wind Turbine Syndrome' And for that, tests are now showing that WTS is a "communicated" disease. The power of suggestion. Perhaps this is also a communicated disease.unfortunately,

Re: [RE-wrenches] outback fx series inverters

2013-04-13 Thread Chris Mason
http://www.greenwavefilters.com/health-risks/ A growing body of evidence points to connections between dirty electricity and a wide variety of physical, emotional, and cognitive health issues. Luckily, they a solution... On Sat, Apr 13, 2013 at 4:16 PM, Roy Butler

Re: [RE-wrenches] outback fx series inverters

2013-04-13 Thread dan
I had one lady in tears when I suggested that she lead her kids into the 21st century an not the other way around.. An I was just trying to get her to wear a digital watch. No, diplomacy is not one of my strong points. But it was an eye opener for me. Original Message

Re: [RE-wrenches] outback fx series inverters

2013-04-13 Thread jay peltz
Hi guys, While I agree that its probably crazy talk. There is one story I have to share. Just like this one, the customer was complaining of the emf's. then she called the install company to say that they were gone!. She didn't know that just that morning the install guys had put a faraday cage

Re: [RE-wrenches] outback fx series inverters

2013-04-13 Thread boB
Todd, I know that you didn't say that the customer was getting headaches, but maybe that is what is making him/her sick ? If so, then may I suggest that what is causing the problem is, instead of EMF, (which I am highly skeptical of), that it may be that the customer is getting sick from the

Re: [RE-wrenches] outback fx series inverters

2013-04-13 Thread Dana
I used to be able to hear 20K HZ no longer am able to, too much great music and dam tools. I have neighbors who live 200' from my array that claimed it was making them sick I had an EMF guy do some readings at the tracker while still reading was 0MG, moving it reading was 12 MG, and moving

Re: [RE-wrenches] outback fx series inverters

2013-04-13 Thread toddcory
i wish i knew what this guy was measuring... rfi, emi, emf, af? it could even be the pwm off the fm80. i dont think an inverter could change any emf to the house as that (gauss) is dependent on current flow. but if there is some rfi from the inverter/cc, riding the 60 hZ ac cables... that

Re: [RE-wrenches] outback fx series inverters

2013-04-13 Thread Hilton Dier III
It's a sad fact of life that people will attribute their ills to whatever is new, strange, or emotionally unappealing to them. In Vermont right now the woo-woos are afraid of wireless internet routers, wireless smart meters, and wind turbines. You have several choices. Call their game - tell