Bizarre, Daniel. I can not imagine that the breaker will open with the tiny PV
current available at first light then handles full current all day without a
problem.
Wild guess here... could it be the Classic transition from open circuit voltage
to operation is creating a momentary short that t
An update on this issue:
On my initial visit to diagnose this problem I changed the AGS settings
higher volt start and % state of charge start. The report from the client
is that this has fixed the AGS issue. So now I am just dealing with the
100 amp breaker tripping.
The trip time from the clie