Greetings Chris,
I used to do a lot of solar thermal installations and rehabs on older
systems. I tried not to use elastomeric type pipe insulation (such as
Armacell/Armaflex and Rubatex Insul-Tube 180) outdoors, because of all
the unsightly and deterioration issues I observed on air conditioning
The issue of off grid power in Florida is fake news misinterpreted from On
Grid Sytems powering a House after s hurricane without a legal transfer
switch . However , it some situations in Florida it is illegal or a major
permit issue not to hook to a city water supply OR have your own well
except f
All HVAC suppliers sell Aluminum or PVC jacketing pipe and fittings for
elastomeric insulation over piping . You can also slide long runs inside
either ABS black pipe either solid or foam core or PVC pipe Sch 20 or 40 or
Electrical Grey Pipe or Schedule 80 Plumbing Pipe - all with couplings .
Elast
Fibered duct mastic works well.
Latex paint can be added for color.
On Nov 4, 2017 9:50 AM, "Ken Schaal" wrote:
> Duct mastic ,fibered, works well.
>
> On Nov 4, 2017 9:13 AM, wrote:
>
>> Chris,
>>
>> The fitted covers certainly provide a more finished appearance. One of
>> my customers painted
Chris,
The fitted covers certainly provide a more finished appearance. One of
my customers painted the insulation (w/o fitted covers) with latex
paint and after 30+ years the insulation was still quite flexible. My
take away was simply that eliminating the sun (UV) effects paid off
big time. As I