Mick,
SMA has something:
http://www.sma.de/en/products/off-grid-inverters/smart-load.html
Dick Ratico
Solarwind Electric
Bradford, VT
--- You wrote:
Step three is most intimidating to me: We need a way to control 240 volt AC
heating elements in a fine pulse width modulated PWM fashion, to
Once again, the Wrench List has proven to be a most valuable resource.
Thanks to all!
Mick Abraham, Proprietor
www.abrahamsolar.com
Voice: 970-731-4675
2010/8/9 Richard L Ratico richard.l.rat...@valley.net:
Mick,
SMA has something:
, Mick Abraham m...@abrahamsolar.com wrote:
From: Mick Abraham m...@abrahamsolar.com
Subject: [RE-wrenches] Advice needed on upsizing a battery grid
interactive inverter stack
To: RE-wrenches re-wrenches@lists.re-wrenches.org
Date: Friday, August 6, 2010, 6:17 PM
Yo, Mechanics~
A client
From: re-wrenches-boun...@lists.re-wrenches.org
[mailto:re-wrenches-boun...@lists.re-wrenches.org] On Behalf Of Mick Abraham
Sent: Friday, August 06, 2010 4:18 PM
To: RE-wrenches
Subject: [RE-wrenches] Advice needed on upsizing a battery grid
interactive inverter stack
Yo, Mechanics
.
darryl
--- On Sun, 8/8/10, bob reelli...@gmail.com wrote:
From: bob reelli...@gmail.com
Subject: Re: [RE-wrenches] Advice needed on upsizing a battery grid
interactive inverter stack
To: 'RE-wrenches' re-wrenches@lists.re-wrenches.org
Date: Sunday, August 8, 2010, 9:39 AM
Can the Outbacks
:
From: Doug Pratt dmpr...@sbcglobal.net
Subject: Re: [RE-wrenches] Advice needed on upsizing a battery grid
interactive inverter stack
To: 'RE-wrenches' re-wrenches@lists.re-wrenches.org
Date: Sunday, August 8, 2010, 11:43 AM
Hi Mick,
We’re increasingly running into this “how big can
, August 06, 2010 4:18 PM
*To:* RE-wrenches
*Subject:* [RE-wrenches] Advice needed on upsizing a battery grid
interactive inverter stack
Yo, Mechanics~
A client is considering a biggest ever for me battery based power system.
They will probably scale down their ambitions once the cost
extra and custom work by outback when it was installed.
Darryl
--- On Sun, 8/8/10, Doug Pratt dmpr...@sbcglobal.net wrote:
From: Doug Pratt dmpr...@sbcglobal.net
Subject: Re: [RE-wrenches] Advice needed on upsizing a battery grid
interactive inverter stack
To: 'RE-wrenches' re-wrenches@lists.re
dmpr...@sbcglobal.nethttp://us.mc519.mail.yahoo.com/mc/compose?to=dmpr...@sbcglobal.net
Subject: Re: [RE-wrenches] Advice needed on upsizing a battery grid
interactive inverter stack
To: 'RE-wrenches'
re-wrenches@lists.re-wrenches.orghttp://us.mc519.mail.yahoo.com/mc/compose?to=re-wrenc
.
Darryl
Darryl .
--- On *Sun, 8/8/10, Mick Abraham m...@abrahamsolar.com* wrote:
From: Mick Abraham m...@abrahamsolar.com
Subject: Re: [RE-wrenches] Advice needed on upsizing a battery grid
interactive inverter stack
To: RE-wrenches re-wrenches@lists.re-wrenches.org
Date: Sunday
Have you
considered a 48 volt generator?
Daryl
--- On Fri, 8/6/10, Mick Abraham m...@abrahamsolar.com wrote:
From: Mick Abraham m...@abrahamsolar.com
Subject: [RE-wrenches] Advice needed on upsizing a battery grid interactive
inverter stack
To: RE-wrenches re-wrenches@lists.re
...@abrahamsolar.com
Subject: [RE-wrenches] Advice needed on upsizing a battery grid
interactive inverter stack
To: RE-wrenches re-wrenches@lists.re-wrenches.org
Date: Friday, August 6, 2010, 6:17 PM
Yo, Mechanics~
A client is considering a biggest ever for me battery based power system
Yo, Mechanics~
A client is considering a biggest ever for me battery based power system.
They will probably scale down their ambitions once the cost realities settle
in but for now they've asked me to look for battery based inverter systems
which can scale bigger than a triple stack of Xantrex