Rushi!(I still have it. It’s in storage now, as I don’t want to risk losing it. Stays on my nightstand, only one-handed operation I know… )On Jan 23, 2024, at 6:47 AM, Roy Butler via RE-wrenches wrote:
Hi Jay,
I get all my Lorentz replacement equipment from Genpro:
Hi Jay,
I get all my Lorentz replacement equipment from Genpro:
https://genproenergy.com/solar-water-pump/
Roy Butler
Four Winds Renewable Energy, LLC
Education is when you read the fine print; experience is what you get when you
don’t.
“The less people know, the more stubbornly they know i
Jay - here is number for
Lorentz USA office in TX:
(806) 728-0110
___
List sponsored by Redwood Alliance
Pay optional member dues here: http://re-wrenches.org
List Address: RE-wrenches@lists.re-wrenches.org
Change listserver email address & setting
Does anyone know if Lorentz pumps still exist in the US.
Someone is looking for a PS200 control box.
It seems to be intermittent
Thx
Jay
___
List sponsored by Redwood Alliance
Pay optional member dues here: http://re-wrenches.org
List Address: RE
ay, February 28, 2018 5:09 PM
To: RE-wrenches
Subject: Re: [RE-wrenches] Lorentz pumps
Jay,
I have one on my own well 480’ down a 800’ deep well. At the time, they could
only handle 500’ but since then have one that can pump from 1000’ and more. I
only sold a few. I did have to replace the circuit b
Jay,
I have one on my own well 480’ down a 800’ deep well. At the time, they
could only handle 500’ but since then have one that can pump from 1000’ and
more. I only sold a few. I did have to replace the circuit board on the
controller a couple of years ago and delt with a Lorentz dealer which
HI All,
I’ve got a client asking me about Lorentz pumps.
I know they have sort of come and gone from the USA.
Is anyone using them, have any pros/cons vs Grundfos and where to get them?
thanks
jay
peltz power
___
List sponsored by Redwood Alliance
Ray, I've been getting Lorentz pumps from "The American West Windmill
& Solar Co." in Abq. the Rep. is Tony Tucker 505 238-8303 or 505 888-5119
Carl
Hansen&Sun Elect.
505 470-0770
On 5/19/2013 1:50 PM, Ray Walters wrote:
Interesting about the licensed pump installer, because in New
Interesting about the licensed pump installer, because in New Mexico
there is not a license. I've been installing PV pumping systems since
1988, so I tire easily now when companies won't work with me, because
I'm not "qualified".
I actually installed some of the "Mono" hand crank and electric p
Allan and all,
I just purchased a Lorentz pump and motor to
replace an ETA HR-14 that ran flawlessly (the ONLY one!) for
10 years.
I did have to establish my creds with Genpro
but then they referred me to a local distributor that
PM
Subject: [RE-wrenches] Lorentz Pumps
Greetings Wrenchies;
I have had a few inquiries for larger flow rate pumps, and was wondering
what the latest on Lorentz pumps was. They show some commercial models
with high flow rates (30,000gpd) but I haven't gotten any response from
the company di
Ray,
I posted this on February 19th. While I believe that GenPro passed
it along to Lorentz (I copied them), I'm not aware that anything
has changed.
Allan
Tom,
Rant:
I would caution you to be very careful working with Lorentz pumps. About 16 months
Hello Ray,
We have had success selling solar pumps, but nothing in the 30,000 gpd
category.
Unfortunately, as I understand it, Lorentz will not sell to anyone that is
not a licensed pump installer. You may talk to GenPro at
http://www.genproenergy.com/lorentz-submersible-pumps.html to get the
la
Greetings Wrenchies;
I have had a few inquiries for larger flow rate pumps, and was wondering
what the latest on Lorentz pumps was. They show some commercial models
with high flow rates (30,000gpd) but I haven't gotten any response from
the company directly.
I have three questions:
Are there
4076
"Responsible Technologies for Responsible People since 1988"
From: re-wrenches-boun...@lists.re-wrenches.org
[mailto:re-wrenches-boun...@lists.re-wrenches.org] On Behalf Of Allan
Sindelar
Sent: Tuesday, February 19, 2013 4:37 PM
To: RE-wrenches
Subject: Re: [RE-wre
Tom,
Rant:
I would caution you to be very careful working with Lorentz pumps.
About 16 months ago we got a service request from a longtime
customer for whom we had installed an ETA (Lorentz) PV-direct
submersible in late 2005. The pump had worked well for n
Hello Wrenches,
Has anyone had recent experience with the Lorentz PS (PV) line of pumps,
both centrifugal and helical? I searched the archives and there was some
feedback on Lorentz pumps two years ago. Just wondering if anyone had anything
more recent.
Thanks,
Tom
Tom DeBates
Habi-Tek
Ge
Kent,
We're dealing with one right now. Installed late 2005, the last Lorentz
we installed because it was at the tail end of all the Lorentz
troubles. So 4 1/2 years in residential use.
We were to pull the pump this morning, but postponed one day because of
heavy overcast. Troubleshooting sugg
Fellow wrenches,
Problems with Lorentz pumps have been discussed here before. Yesterday,
I responded to a no water complaint and found that the Lorentz pump we
installed in 2007 appears to have seized up during six months of non-use
(it's for stock water). This is the second identical failur
19 matches
Mail list logo