[RE-wrenches] SunPower and SMA

2011-01-28 Thread Marco Mangelsdorf
Have any of you SunPower dealers used their modules with the fairly new SMA line of transformerless inverters (8, 9 and 10 kW @ 120/208 only)? I'm trying to get a compatibility answer directly from SunPower tech support, but am wondering if any of you have tried this combo. Thanks, marco

Re: [RE-wrenches] Sunpower and SMA

2011-02-10 Thread Tom DeBates
Have any of you SunPower dealers used their modules with the fairly new SMA line of transformerless inverters (8, 9 and 10 kW @ 120/208 only)?   I’m trying to get a compatibility answer directly from SunPower tech support, but am wondering if any of you have tried this combo.   Thanks,

Re: [RE-wrenches] Sunpower and SMA

2011-02-10 Thread Marco Mangelsdorf
I’ve used that line, Tom, with non-SunPower mods. Those three models definitely should NOT be used with SunPower modules due to the fact that there’s no grounded current-carrying DC conductor in the circuit. marco Have any of you SunPower dealers used their modules with the fairly new