HI Howie,
That would have been the PS inverter, not the SW that had the RC8 remote
control.
But I agree with you on the reliability of the TM500. I’ve taken out many that
have failed or worse have been random in % readings. I’ve replaced them with
Trimetrics. So I don’t recommend the TM500.
Hey Allan,
I don't know about the wiring of the on/off switch - I'm not sure it is
simple logic. I do believe it worked for the trace SW, not sure about the
DR.
I wouldn't recommend using the TM500 - I ran into a significant problem
with it when used with an SW and a C40 back some 17 years ago, wh
Esteemed Wrenches, graybeard (used here as a gender-neutral term)
contingent:
I am putting together a low-cost off grid upgrade package for my nearest
neighbor out here, who has lived with a most basic system with little
upgrade since the 80s. She needs a sinewave inverter to run a modern
was