Re: [RE-wrenches] Well pump relay question

2014-04-09 Thread Ray Walters
I've had the contacts arc and not disconnect at 144 vdc. I used a modified relay from an electric vehicle company: KTA services. R.Ray Walters CTO, Solarray, Inc Nabcep Certified PV Installer, Licensed Master Electrician Solar Design Engineer 303 505-8760 On 4/4/2014 7:06 AM, Michael Morningst

Re: [RE-wrenches] Well pump relay question

2014-04-04 Thread Michael Morningstar
I've done just that with DC rated 24VDC relays intended for marine and heavy equipment applications. No arcing while disconnecting SQFlexes under load. On Apr 3, 2014, at 11:06 PM, Allan Sindelar wrote: > Wrenches, > For my own off grid home, I would like to add four 60-cell modules as a > supp

[RE-wrenches] Well pump relay question

2014-04-03 Thread Allan Sindelar
Wrenches, For my own off grid home, I would like to add four 60-cell modules as a supplemental array, using a Midnite Classic charge controller. I would like to set up a relay between this array and the controller to allow me to direct the output to an SQFlex submersible