Dear All,
can anyone of you send me the CIF or the coordinate of CuAlO2?
It has the following lattice parameters: a=2.85, c =16.94 alpha = beta
= 90, gamma = 120, V = 119.7. Space group R-3m Hexagonal (Rhomhedral,
No 166).
many thanks in advance.
stephen
Dear Rietvelders,
Please use my new email a/c chui...@hkucc.hku.hk.
The current email will be not removed soon.
best regards
stephen
Dear all,
does anyone of you know how to find/specify the non-bonded distances with esd
in the GSAS/EXGUI? I checked the output file from DISAGL, but there
are only distances between "chemical bonds". can i specify a given
atom pair for distance calculation?
many thanks in advance
best reg
Dear Ross,
How about the LP factor/monochromator angle if using Gobel mirror in
my D8 system?
Thanks!
stephen
- Message from ucca...@ucl.ac.uk -
Date: Thu, 23 Jul 2009 09:52:55 +0100
From: Ross H Colman
Reply-To: Ross H Colman
Subject: Re: LP factor in the Rietveld r
Dear all experts in XRD,
As stated in the header, does anyone know if there is some software(s)
available for estimation of average crystal grain size using the peak
breath of XRD data? I just want to know some rough values so as to
compare my samples prepared at different conditions. Many
Dear all,
Recently, I have refined the structure using powder data. In each
asymmetric unit of Pmc21, there are two chemically similar but
crystallographically different complexes. The center of these two
complexes is rougly around 0,0,0.75. Therefore, the true space group
may not be Pmc2
Dear all rietvelders,
Do anyone of you use the ball miller for PXRD sample preparation?
Since I am going to buy one such system. Any comment is highly
appreciated.
many thanks in advance
stephen
Dear all rietvalders,
Can anyone of you kindly send me the atomic coordinates?
1) Cu2Se cubic form (PDF-2 71-0044 a = 5.7650, Fm-3m)
2) Cu2Se cubic form (PDF-2 76-0136 a = 5.84, F23)
3) Cu2Se tetragonal form (PDF-2 53-0523 a = 11.510, c = 11.740, P4/mmm
or P42/n)
many thanks
stephen
Dear Sir/Madam,
can you please to replace my current email address ([EMAIL PROTECTED])
with the new one:
[EMAIL PROTECTED]
because the former will be removed.
many thanks
stephen
Dear all rietvelders,
would anyone of you kindly provide me the atomic coordinates of Cu2Se
(Berzelianite, Powder Diffraction File PDF-2 071-0044, Cubic Fm3m)?
Great appreciate!
cheers
stephen
Dear All rietvelders,
can you remind me what the peak position of the tungsten L-alpha for the Cu
X-ray tube? I am curious to estimate the lifetime of our Xray tube used for 2
year.
many thanks
stephen
Dear all,
thank a lot.
stephen
Quoting Jacco van de Streek <[EMAIL PROTECTED]>:
> [EMAIL PROTECTED] wrote:
> > can anyone of you know something about this issue?
> > Thank you for your help.
>
> Dear Stephen,
>
> tables with values for covalent and vdW radii for organic and
> organometallic
Dear all,
can anyone of you know something about this issue?
Thank you for your help.
regards
stephen
Dear all,
Thank you very much for your information.
I think the one I am using is Si[111]. It was used for checking the linearity
of the diffractometer.
I just curious to see some rietveld refinement can be practised myself.
I got R-factor (R(F2)) ca. 15% and the simulated PXRD from Si structure
Dear colleagues
can anyone remind me the space group and lattice constants of the Si standard
(flat plate) used in the Philips APD B-B diffractometer? Since I will like to
do some comparison studies using GSAS.
Many thanks,
regards
stephen
Dear all,
Can anyone know how to optimize the intermolecular contacts of say, a rigid
organic molecule such as naphthalene etc if we know there is no occluded solvent
molecule but the cell volume/density is too far from typical range?
In case of any ambiguity, please feel free to discuss.
many t
Dear Rietvelders,
Does anyone can provide the sources for purchasing XRD standards materials, such
as CeO2 and Y2O3?
I need few grams of these for calibration of our XRD.
Thank in advance.
regards
stephen
Dear Rietvelders,
I am using the updated version of GSAS and will like to know bit more about the
following feature(s)?
In the histogram editing menu, What is the physical meanings of the R-free
sampling factor and seed - (option S) ? How these affect the refinement
result?
Hope that this will n
Dear Rietvelders,
Does anybody encounter a problem stated "time out during data collection" in
using the APD program of a Philips XRD system? It is annoying because the XRD
will automatically stop the data collection. I checked through the manual but
does not know what this about.
Please advise m
Dear All,
By the way, does anybody know where i can buy parts (eg slits) for Philips APD
diffractometer (PW3710)? since this model is already out of date.
Many thanks
stephen
Quoting James Talbot <[EMAIL PROTECTED]>:
> I recommend Jim Stauver located here in Texas. His website is
> http://w
users.
many thanks,
stephen chui
Quoting William Bisson <[EMAIL PROTECTED]>:
> Dear Chuisy,
>
> The broad bump you are experiencing at low angle may be to do with the
> slits. One has to be careful with these new XRD machines which have
> variable slits, to make sure
Dear all,
We are recently installing a XRD, and there is a huge peak occurred in the
3-7deg (2T) which is masking the useful signals from the sample. How can we
eliminate the big peak there?
We use 40kW, 30mA CuKa x-ray, divergent and receving slits are used,
many thanks,
stephen
Dear all rietvalders,
I am the beginner of using synchrontron xray data for structural analyses.
However i don't know whether i can use the original xry.prm file in GSAS to
parameterize the synchrotron data for refinement. Please advise me
Many thanks,
stephen chui
Dear all,
well I do think it works ok. but i don't know why the held parameters are
still there when i go back there again after doing the POWERPREF, GENLE.
However, I create an new EXP file and input all things back, it resumes ok.
thank you very much for your kind attention.
stephen
Dear all Rietvalders,
Can anyone know how to delete the holding parameter (F option under the atomic
parameter menu in GSAS)? since the program does not allow me to remove them
even after pressing "D" for those variables? They are still there anyway.
many thanks
stephen
Dear all Rietvalders,
Can anyone know how to delete the holding parameter (F option under the atomic
parameter menu in GSAS)? since the program does not allow me to remove them
even after pressing "D" for those variables? They are still there anyway.
many thanks
stephen
Dear All rietvalders,
a question about sample transparency in GSAS is asked. is there any physical
meaning when its value is positive or negative? Is the sample density
correlated somehow with it? since my sample becomes less dense and the neg.
trns value was obtained.
Hope that it won't be too
Dear Robert B.Von Dreele
Thank you for your explanation.
Therefore GSAS could do the origin fixing for us when the space group is not
centrosymmetric. Can I boardly say that?
regards,
stephen
Kurt
> I think that P2/n has no fixed points, and in order to keep the whole
> structure from shifting along the c-axis, one of the atoms has to be
> arbitrarily fixed. GSAS automatically fixes the first atom z-parameter (was
> your atom on the 2-fold symmetry axis?). I remember this from refini
Dear Rietvelders,
I used GSAS to refine my structure in P2/n, however the program automatically
fixed the the XYZ positions of the first atom during refinement. To my
surprise, this atom is not seen in the "fixed atom list" in the atom parameters
menu of GSAS.
Please advise and many thanks,
step
Dear all Rietcelder,
Can anyboby tell me the difference between these two space groups?
P63m m c and P63m c m?
many thanks,
stephen
31 matches
Mail list logo