Re: Occupancy factors for mixed site in TOPAS

2019-02-20 Thread François Goutenoire
Thanks to every one. It was not so difficult in fact . Best whishes, François Le 19/02/2019 à 11:02, François Goutenoire a écrit : Dear Rietveld users, One more question ! I am unable to find the way to constraint occupancy factor for mixed sites in Topas in GUI mode. Sorry for this basic

Re: Occupancy factors for mixed site in TOPAS

2019-02-20 Thread Matthew Rowles
Hi François You need to use codewords and equations. In the sites section of the structure, give the occupancy of one element a name (eg al_occ), and then for the other atom on the same site, give it an equation in the codes tab (eg =1-al_occ;) You would then put min/max limits on the first atom

Re: occupancy

2007-12-04 Thread Daniel Toebbens
Igor Djerdj schrieb: The following question is addressed more to FULLPROF users. I want to refine atomic occupancies of Fe-doped TiO2 for instance. Assuming that Ti is substituted with Fe at some sites, how can I provide that the sum of occupancies of Fe and Ti is 1 or 100%? There are two op

RE: occupancy

2007-12-04 Thread Matthew.Rowles
Can you set up equations in FullProf? Refine the occupancy of Ti and set occ(Fe) = 1 - occ(Ti). Cheers Matthew Matthew Rowles CSIRO Minerals Box 312 Clayton South, Victoria AUSTRALIA 3169 Ph: +61 3 9545 8892 Fax: +61 3 9562 8919 (site) Email: [EMAIL PROTECTED]

RE: occupancy

2007-12-04 Thread Yokochi, Alexandre
Igor, Back when I used to do this a lot, the easiest way was to just start the occupancy of the two sites at 1 (e.g., 95% + 5%) then give one site a given variable and the second the opposite sign for the same variable (e.g., 20.5 and -20.5). I've been out of the XRD game for a few years, so

Re: Occupancy Constraint...

2007-02-25 Thread Daniel Toebbens
[EMAIL PROTECTED] schrieb: I am using FULLPROF 2006 for the analysis of my system. I am having one problem in defining the constraint. Actually I have 4 cations in my system and want to put a constraint as w+x+y+z=1. Is it possible to define such constraints using FULLPROF. In principle i

RE: Re: Occupancy Constraint...

2007-02-25 Thread Whitfield, Pamela
[mailto:[EMAIL PROTECTED] Sent: Sun 25/02/2007 1:03 AM To: rietveld_l@ill.fr Subject: Re: Occupancy Constraint... Dear Geetika This will not answer your question, buy maybe allows you change it. As has been discussed several times in the Rietveld list, the only way to refine the occupancy of x cat

Re: Occupancy Constraint...

2007-02-24 Thread Leopoldo Suescun
Dear Geetika This will not answer your question, buy maybe allows you change it. As has been discussed several times in the Rietveld list, the only way to refine the occupancy of x cations in certain site is to have x or more independent determinations of the scattering power of that site. In y