On your Riv machine, can you load the page
http://localhost/rd-bin/addcart.html?
If you can't check your apache setup is correct and has the Rivendell
web stuff in the right place.
Wayne Merricks
The Voice Asia
On 29/05/15 01:23, Stan Fotinos wrote:
Hi Ryan
Do you have the mpeg2 encoder
Since we do this all the time with a BT ACS8.2 switcher, let's review
some steps:
In your serial port setup in rdadmin, did you also define (as in add)
a switcher in the Switchers GPIO section? It seems that the SRC-16
switcher is a choice here.
In your testing with minicom, if you
Like I said, all I did was follow these instructions posted on this website:
http://www.talkunafraid.co.uk/2011/06/rivendell-2-0-2-on-ubuntu-10-04-2-lts/
And install Icecast2
On 5/29/15, Wayne Merricks waynemerri...@thevoiceasia.com wrote:
Looks like you've fell victim to Apache not being set up
All I'm getting is when I go to localhost/rd-bin/addcart.html and (IP
Address)/rd-bin/addcart.html was the following
Not Found
The requested URL /rd-bin/addcart.html was not found on this server.
Apache/2.2.14 (Ubuntu) Server at localhost/(IP Address) Port 80
My IP was 10.0.2.15
On 5/29/15,
Hi James;
Thanks for the reply.
Here's the latest. We have 3 Rivendell systems all are V2.10.3. Two are from
the appliance disk one is compiled from source. All work with Mincom. But
only the one works from Rivendell and that one is the, complied from source,
machine. BTW the other 2 machines send
Looks like you've fell victim to Apache not being set up with the Riv
config properly.
You can check to see if there are any enabled sites for Riv in the
apache config directory (/etc/apache2/conf.d/sites-available I think)
Or all I did last time this happened to me was copy the entire