Hi,
On Mon, Sep 26, 2005 at 06:56:08PM -0500, Dan McGhee wrote:
I have already looked at Rene's SVN and the patch and there doesn't
seem to be any relevant change in the above mentioned part of the
code.
I'm sorry, but I disagree. The sequence you noted previously is
currently in Rev
[segfault of xscanimage with avision backend]
On Sat, Sep 24, 2005 at 07:39:51AM -0500, Dan McGhee wrote:
Starting program: /usr/bin/xscanimage
*[This is the point at which I clicked scan in the preview window]*
Program received signal SIGSEGV, Segmentation fault.
0x08057467 in gsg_sync
Henning Meier-Geinitz wrote:
[segfault of xscanimage with avision backend]
On Sat, Sep 24, 2005 at 07:39:51AM -0500, Dan McGhee wrote:
Starting program: /usr/bin/xscanimage
*[This is the point at which I clicked scan in the preview window]*
Program received signal SIGSEGV, Segmentation
Hi,
On Sun, Sep 25, 2005 at 11:13:56AM -0500, Dan McGhee wrote:
Just to remind you, I'm not using the version of avision released in
backends-1.0.16. I'm using Rev. 280 of avision from SVN. It is patched
with the file Falk Rohsiepe sent me and then Rene posted a patch here
last month.
I
Henning Meier-Geinitz wrote:
could you also run xscanimage with gdb as mentioned in my previous mail?
Here's the output of gdb:
Starting program: /usr/bin/xscanimage
*[This is the point at which I clicked scan in the preview window]*
Program received signal SIGSEGV, Segmentation fault.
Hi,
On Thu, Sep 22, 2005 at 05:58:28AM -0500, Dan McGhee wrote:
Here is the info from close to the end of the file from
SANE_DEBUG_AVISION output when running xscanimage:
could you also run xscanimage with gdb as mentioned in my previous mail?
Bye,
Henning
Henning Meier-Geinitz wrote:
Hi,
On Wed, Sep 14, 2005 at 06:08:03PM -0500, Dan McGhee wrote:
Using sane-backends-1.0.16, I patched rev 280 of Avision, from SVN, with
the patch from Falk Rohsiepe that Rene Rebe published. My scanner now
works using xsane.
However, when using xscanimage in
Using sane-backends-1.0.16, I patched rev 280 of Avision, from SVN, with
the patch from Falk Rohsiepe that Rene Rebe published. My scanner now
works using xsane.
However, when using xscanimage in either preview or scan, the
application exits with a segmentation fault. Setting the debug level