Re: Subsurface Planner: feature request

2017-01-23 Thread Anton Lundin
On 23 January, 2017 - Robert Helling wrote: > Hi, > > > On 21.01.2017, at 16:53, Anton Lundin wrote: > > > > I would love to see a simple way to switch between combinations of deco > > gases. Its quite a few times I'm wondering its it worth it to carry the > > 100%, 50% or what happens of we st

Subsurface Planner: feature request

2017-01-22 Thread Stefan Fuchs
Hi All, >>/Am 21.01.2017 um 13:28 schrieb Rick Walsh http://lists.subsurface-divelog.org/cgi-bin/mailman/listinfo/subsurface>>: />>//>>/set the switch depth of the deco gas to either deeper than the max depth of the dive (so you never switch to it), or very shallow (0.1m, so it has negligible effe

Re: Subsurface Planner: feature request

2017-01-21 Thread Anton Lundin
On 21 January, 2017 - Robert C. Helling wrote: > Hi, > > > Am 21.01.2017 um 13:28 schrieb Rick Walsh : > > > > set the switch depth of the deco gas to either deeper than the max depth of > > the dive (so you never switch to it), or very shallow (0.1m, so it has > > negligible effect on the pla

Re: Subsurface Planner: feature request

2017-01-21 Thread Robert C. Helling
Hi, > Am 21.01.2017 um 13:28 schrieb Rick Walsh : > > set the switch depth of the deco gas to either deeper than the max depth of > the dive (so you never switch to it), or very shallow (0.1m, so it has > negligible effect on the plan). Alternatively, you first plan the dive with all gases, sa

Re: Subsurface Planner: feature request

2017-01-21 Thread Rick Walsh
On 21 Jan 2017 10:42 PM, "Willem Ferguson" wrote: In planning it it required to consider the failure of a deco tank since this affects the safety margin required from gases in some of the other tanks. Therefore one would like to disable one of the tanks in the Available Gases table. Currently one

Subsurface Planner: feature request

2017-01-21 Thread Willem Ferguson
In planning it it required to consider the failure of a deco tank since this affects the safety margin required from gases in some of the other tanks. Therefore one would like to disable one of the tanks in the Available Gases table. Currently one needs to delete the tank and then enter all the