Re: [Elphel-support] sensor board, informations

2017-02-10 Thread Elphel Support
Hello Julie, I'm afraid we can not help you with the sensor boards compatible with Raspberry Pi - our sensor boards are only compatible with the earlier Elphel cameras, designed more than 10 years ago. All our sensor boars use the 30-conductor flex cables - we can use both standard 0.5 mm pitch

[Elphel-support] sensor board, informations

2017-02-10 Thread julie
Hi, :-) I'm in a french team of film makers, and we want to build an open source camera. We are looking for an high or average definition (at least 1920x1080) open source Sensor Board compatible with raspberry Pi, that could allow use to use any objective (including old photographic objective). W

Re: [Elphel-support] Elphel 353 server

2017-02-10 Thread Daniel Rouan
Many thanks Oleg for your advices. It works now with the sensor connected to J2. The web server is now OK and I got images. Finally it was indeed a question of cable and proper connection. By the way the small plastic clip that presses the cable on the pins of the connector is broken and I re

Re: [Elphel-support] Elphel 353 server

2017-02-10 Thread Daniel Rouan
Oleg, Sorry for the flood of messages… Apparently I can send commands through the port 8081, such bimg, but for instance the image returned is 1 px gif. As if the sensor was not actually running. Is there some command to make a deeper test ? Daniel Le 10 févr. 2017 à 13:36, Daniel Ro

Re: [Elphel-support] Elphel 353 server

2017-02-10 Thread Daniel Rouan
Oleg,Just after ending the previous email, I changed to the connector that  is theclosest from the DC/DC converter FKC08-48. (silver box) and the msg returnedby dmesg is changed : the sensor is found ! (see attached).But, the browser (firefox) cannot connect anymore.regards,  Daniel {\rtf1\ansi\ans

Re: [Elphel-support] Elphel 353 server

2017-02-10 Thread Daniel Rouan
Oleg, I changed the cable with a spare one (for my application I had to buy longer cables) but the result is the same. By the way I'm doing the tests with one unique sensor (the other one is at another place, far away) : is that a problem ? are the 3 connectors on the mux board equivalent to m