Om,
Here is the setup: Two micaz nodes, 143 is the root with ID 500, 141 is the
other node.
142 is a basestation close there...
Thanks,
Yiannis
[EMAIL PROTECTED] BaseNetwork]$ java -classpath tinyos.jar
net.tinyos.tools.Listen -comm
[EMAIL PROTECTED]:10002
[EMAIL PROTECTED]:10002:
Wanted to say that 141 is the root with ID 500, and 143 the other node with ID
2. (142
still being the BaseStation)..
Sorry about that,
Y.
Yiannis Yiakoumis wrote:
Om,
Here is the setup: Two micaz nodes, 143 is the root with ID 500, 141 is the
other node.
142 is a basestation close
Hi Phoebus,
How did you solved this problem. I am also getting the same error and I am
unable to find any help. If you find the solution please let me know
Thanks in advance.
-Raj
On Wed, Sep 19, 2007 at 8:17 AM,
OK, I will and let you know when I have any news.
By the way, is address filtering platform specific, or something that could
work on telosb
and not in micaz?
Y.
Omprakash Gnawali wrote:
I remember having a similar problem and I got CTP to work only after
disabling address filtering. Then I
hi.
thanks a lot for your answer. Philip.
I try to test mote transmission time outdoor, but results are the same as
before ( no intereference with other 2.4G Hz traffic).
The ACK listening time is always ( default) implemented in cc2420 radio
stack of telosb motes? cause my mote sends
messages
I think it should be better to send questions to the group. That message was
sent to the list several months ago. I tried to adapt the transmission power
in TOSSIM.
Now I am using TinyOS 2.x. I think CC1000RadioC is what you are looking for
(If I still remember).
Ittipong
2008/6/10 王薇 [EMAIL
Hi,
I am using Tinyos2.0.2 with cygwin on a Windows xp machine. There is a
different platform on which i used to compile and install applications
successfully, but now when i execute :
make 'platformname' install jtag_TIUSB, i get the following error :
LoadLibrary(pythondll) failed (Module not
Hi TinyOS users!!
I'm trying to install Deluge on my motes. I'm following every step I read on
the Deluge T2 manual, but, when I try to compile TOSBoot, I get a lot of
errors. Do MICA2 motes support Deluge T2? However, if I try to compile TOSBoot
for MICAz or TELOSB (as seen in the example
hi, all
who once tried to use the application of tinyos2.x to 1.x, are there
something compatible ? or it can be used after some modification.
thanks
___
Tinyos-help mailing list
Tinyos-help@millennium.berkeley.edu
Hi,
I solved the problem with copying python24.dll in the directory of
my UsbJtag executable to which my platform points.
Cheers.
Kaan
On 6/10/08, Kaan Tuna [EMAIL PROTECTED] wrote:
Hi,
I am using Tinyos2.0.2 with cygwin on a Windows xp machine. There is a
different platform on which i used
On Tue, Jun 10, 2008 at 12:08 AM, Yiannis Yiakoumis
[EMAIL PROTECTED] wrote:
OK, I will and let you know when I have any news.
By the way, is address filtering platform specific, or something that could
work on telosb and not in micaz?
It should work on both the platforms but I suspect that
I have one basic question: I am using XubunTOS. Suppose that some part of
TinyOS 2.x is modified on CVS, for example, one interface is changed, how do
I update the XubunTOS I am using?
Do I have to manually copy the modified interface from CVS to my XubunTOS?
Thanks,
Gary
I would like to write some code to flush the radio buffer immediately
(no split phase functions or tasks).
So I tried the following code:
call CSN.set();
call CSN.clr();
call SFLUSHRX.strobe();
call SFLUSHRX.strobe();
call CSN.set();
But this doesnt completely
Hi,
I'm porting tinyos 2 to the new msp430 family.
The main problem is that tha USART device has changed to the USCI device,
so all serial comunications changed (specially ones comunicating with
CC2420).
For the moment i managed to run tinyos (and send and receive packets) on a
msp4302617 based
Hi (specially to those who have been involved in implementing Tinyos 2 to
msp430),
I'm porting TinyOS 2 to the new msp430 family (which has a USCI instead of
an USART).
I'm trying to maintain as possible the same architecture as already
implented code (I called new folder inside chips msp430X
Hi everyone:
Hope to gain some warm responses from you!
After make mica2 reinstall mit510, com4 succeeded, I coundnt query the
data from the Mote through the MoteView, can i reset the platform to
previous status? Thanks!
Sincerely;
Maggie
___
Hi!
On Tue, 10 Jun 2008, Antonio Prados Vilchez wrote:
Hi TinyOS users!!
I'm trying to install Deluge on my motes. I'm following every step I
read on the Deluge T2 manual, but, when I try to compile TOSBoot, I get
a lot of errors. Do MICA2 motes support Deluge T2? However, if I try to
Hello people,
I have posted a message like this, but I think it was not very clear,
so let me see now.
I'm developing an application similar to BaseStation that
read something in the serial port and send to radio interface.
I'm facing some problems to simulate the application.
As you can see
It seems that something else is going on...
This is the output, after a fresh restart and/or address filtering ( I did this
through
-DCC2420_NO_ADDRESS_RECOGNITION, is this correct? ).
In both cases root node has id 500.
If I interpret the packet correct (ID=0x18, 2 bytes for
Hi,
Why CTP is not performent why the number of nodes in network is high!!!
I don't find a logic answer.
Thank you,
Nahr Elk
___
Tinyos-help mailing list
Tinyos-help@millennium.berkeley.edu
I want to say* when* the number of nodes in the network is high
-- Forwarded message --
From: Nahr ... [EMAIL PROTECTED]
Date: 10 juin 2008 21:56
Subject: high density and CTP
To: tinyos-help tinyos-help@millennium.berkeley.edu
Hi,
Why CTP is not performent *why* the number of
On Jun 10, 2008, at 11:38 AM, Yiannis Yiakoumis wrote:
If I interpret the packet correct (ID=0x18, 2 bytes for
LinkEstimator, 1 byte option, 2
bytes parent,...) micaz root sends the packet with the wrong parent
(0001).
(I use set-mote-id in Mirage in order to set the id (after
Thanks for posting a solution.
Paul
___
Tinyos-help mailing list
Tinyos-help@millennium.berkeley.edu
https://www.millennium.berkeley.edu/cgi-bin/mailman/listinfo/tinyos-help
I suspect the funneling problem is coming into play. (Although since
the original message is vague, the rely is more or less a general
suggestion.) That is, nodes can only send so many packets/data in a
given period of time: the nodes closer to a sink tend to get clogged
up trying to handle the
In component `BaseStationC':
BaseStationC.nc:79: ambiguous match
make: *** [sim-exe] Error 1
Fix this.
1) Ensure that you have no name collisions.
2) Try to specify the target component interface explicitly.
3) Go back to when in stopped worked and find out what was changed.
HTH,
Paul
hi everyone:
I want to ask a question, before coding on the programming platform such as
mib50. what coding exits in mib510??
Thanks!
Sincerely;
Maggie
___
Tinyos-help mailing list
Tinyos-help@millennium.berkeley.edu
Hi Paul,
I added .Receive in the following line and works fine.
79 BaseStationP.UartReceive - Serial.Receive;
Thanks a lot
On Tue, Jun 10, 2008 at 4:47 PM, Paul Stickney [EMAIL PROTECTED] wrote:
In component `BaseStationC':
BaseStationC.nc:79: ambiguous match
make: *** [sim-exe] Error 1
Hi, there,
Following the deluge T2 tutorial, I tried to test Quick Start on Iris.
When the command ./burn /dev/ttyUSB0 iris was executed, an error
occured as follows:
Please install PySerial first.
I've installed the latest CVS and the python scripts following the
Tools Installation section.
hi everyone:
I want to ask a question, what is the function of Reset Button on MIB510?
If I upload some coding on the programming board such as mib50 not
successfully, can I use the reset button to get the initial state of
MIB510?
Thanks!
Sincerely;
Maggie
XubunTOS has tinyos release version 2.0.2 which is not cvs updatable. You
will have to check out the entire tinyos-2.x directory from the CVS
repository into a separate directory.
On Wed, Jun 11, 2008 at 12:42 AM, Gary Lee [EMAIL PROTECTED] wrote:
I have one basic question: I am using
I want to understand the details of AODV code implemented in the contrib/HSN/
directory of Tinyos. Please guide me from where I can get the
documentation/tutorial.
regards
sajida
__
Sent from Yahoo! Mail.
A Smarter Email
Yep,
Actually TOS_NODE_ID was set, but ActiveMessageAddress did not which led to all
this
trouble...
Thanks,
Y.
Philip Levis wrote:
On Jun 10, 2008, at 11:38 AM, Yiannis Yiakoumis wrote:
If I interpret the packet correct (ID=0x18, 2 bytes for LinkEstimator,
1 byte option, 2
bytes
Dan,
The error message is correct: you have to install PySerial separately.
You can get it from http://pyserial.sourceforge.net/
Janos
-Original Message-
From: [EMAIL PROTECTED]
[mailto:[EMAIL PROTECTED] On Behalf Of Dan
Sent: Tuesday, June 10, 2008 6:07 PM
To:
hi jiwen,
looking at the cvs head, CC2420CsmaP.nc provides interface RadioBackoff
(http://tinyos.cvs.sourceforge.net/*checkout*/tinyos/tinyos-2.x/tos/chips/cc2420/csma/CC2420CsmaP.nc?revision=1.4)
you may want to update your CVS.
brano
jiwen zhang wrote:
Hello brano :
can you give me
Janos,
Thank you so much. It went through. PySerial is not shipped with Xubuntos.
Dan
On 6/10/08, Janos Sallai [EMAIL PROTECTED] wrote:
Dan,
The error message is correct: you have to install PySerial separately.
You can get it from http://pyserial.sourceforge.net/
Janos
-Original
35 matches