Thanks, Adrian & Louis.
I should have remembered about making the line longer to allow for control
characters - I do this for CSV files at times.
Mike, I do SETPTR mode 3 CAPTURING HOLD.ID, and later on SPOOL &HOLD&
FIELD(HOLD.ID,' " ', 2). Can't remember why the FIELD is necessary, but it
all work
ource for Integrated EDI Translation and DataSync Integration
www.sysmarkinfo.com
- Original Message -
From: "HENDERSON MIKE, MR" <[EMAIL PROTECTED]>
To:
Sent: Sunday, July 31, 2005 7:04 PM
Subject: RE: [U2] PCL Codes taking character positions [UV] {Unclassified}
> David
David,
> -Original Message-
> From: [EMAIL PROTECTED]
> [mailto:[EMAIL PROTECTED] On Behalf Of
> Norman, David (SAAS)
> Sent: Monday, 1 August 2005 12:05
> To: 'u2-users@listserver.u2ug.org'
> Subject: [U2] PCL Codes taking character positions [UV]
[sn
ROTECTED]>
To:
Sent: Monday, August 01, 2005 8:59 AM
Subject: Re: [U2] PCL Codes taking character positions [UV]
: Hi David,
:
: Each character of the control sequence MUST take up one character in
: the &HOLD& file. I suspect that the printer will action them and
: suppress them. T
PROTECTED] On Behalf Of Norman, David
(SAAS)
Sent: Monday, 1 August 2005 8:05 AM
To: 'u2-users@listserver.u2ug.org'
Subject: [U2] PCL Codes taking character positions [UV]
Morning,
I am having a problem with PCL codes taking character positions when
spooling to &HOLD&.
If I print dir
printed.
Catch my drift?
Louis
- Original Message -
From: "Norman, David (SAAS)" <[EMAIL PROTECTED]>
To:
Sent: Monday, August 01, 2005 8:05 AM
Subject: [U2] PCL Codes taking character positions [UV]
: Morning,
: I am having a problem with PCL codes taking character posi
Morning,
I am having a problem with PCL codes taking character positions when
spooling to &HOLD&.
If I print direct to the printer (SETPTR mode 1) then PCL codes such as
Bold/unbold do not take character positions and I can print 80 characters on
a line.
If however I print to &HOLD& using mode 3, a