Sagar, Please always copy the list when asking for support.
Something is wrong with your init string in that case.
From: Sagar Deshpande [mailto:sdeshpa...@ravy.co.in]
Sent: dinsdag 4 juni 2013 7:27
To: Rene Kluwen
Subject: Re: reading received messages in kannel
Thanks for your
Could not receive the sms with configuration:
group = core
admin-port = 13000
smsbox-port = 13001
admin-password = hello
log-file = /var/log/kannel/bearerbox.log
access-log = /var/log/kannel/access.log
box-allow-ip = 127.0.0.1
box-deny-ip = *.*.*.*
#log-level = 0
group = smsc
smsc = at
i am getting the below log when i receive a message:
2013-06-04 14:18:59 [9716] [4] INFO: AT2[/dev/ttyACM0]: opening device
2013-06-04 14:18:59 [9716] [4] DEBUG: AT2[/dev/ttyACM0]: device opened.
Telnet mode = 0
2013-06-04 14:18:59 [9716] [4] DEBUG: AT2[/dev/ttyACM0]: device opened
2013-06-04
Hello Experts,
Getting below error in one of my SMPP connectivity:
*SMSC returned error code 0x0439 (Vendor-specific error, please refer
to your SMPP provider) in response to submit_sm.*
Unable to find any detail on the net.
Please help.
Regards
Santosh
Ask your provider about error, it depends on their soft
04.06.2013 14:43 пользователь Santosh Bhabal sant...@thinkwalnut.com
написал:
Hello Experts,
Getting below error in one of my SMPP connectivity:
*SMSC returned error code 0x0439 (Vendor-specific error, please refer
to your SMPP
The easiest way is to set log-level to 0 and you can find the human readable
status in submit_sm_resp. Refer to it please check your telco's documentation
to check it's definition.
Willy Mularto
sangpr...@gmail.com
On Jun 4, 2013, at 5:41 PM, Santosh Bhabal sant...@thinkwalnut.com wrote:
Hi
Some nokia phones does not support CNMI command nor EM message
storage. You should use SM.
For this app, better use a non Nokia phone.
Regards
Alvaro
On 6/4/13, Sagar Deshpande sdeshpa...@ravy.co.in wrote:
Could not receive the sms with configuration:
group = core
admin-port = 13000
There is also another possible issue.
SMSC may use different algorithm to calculate the throughput than Kannel
use.
For example SMSC may rely on exact delays between PDUs or check number of
messages retrieved during 1 sec since last submit_sm PDU retrieved.
I've faced such issue couple of years
Hi Santosh,
439 is in hexadecimal, if we convert it to decimal it becomes 1081. Try to find
this 1081 error means in your telco specific documentation.
Willy Mularto
sangpr...@gmail.com
On Jun 4, 2013, at 9:05 PM, Michael Bochkaryov mi...@rattler.kiev.ua wrote:
There is also another
Hi kannel users,
Right now I'm testing opensmppbox and it's running correctly, but there is
a problem, the sms seems to be slow to delivery to the smscenter, I have
run some test and it seems that the throughput it is set to 10m/s.
I have the following configuration for the smsc:
group = smsc