Re: [QE-users] pw.x - choosing starting_magnetization value for specific expected total magnetization

2024-02-23 Thread Abdul Muhaymin via users
Thanks Guido. I understand this starting_magnetization switch now. I wasn't using DFT+U since I first wanted to see what happens without any U correction and planned to use U correction later. But this is a good suggestion to set a near 0 U value to have the occupation matrix in the output. I

Re: [QE-users] pw.x - choosing starting_magnetization value for specific expected total magnetization

2024-02-22 Thread Paolo Giannozzi
Actually this is going to change in the next release: - if -1 < starting_magnetization < 1, it works as described below - if |starting_magnetization| >= 1, it is the starting magnetization in Bohr magnetons Paolo On 22/02/2024 16:47, Guido Fratesi wrote: Dear Abdul, the starting

Re: [QE-users] pw.x - choosing starting_magnetization value for specific expected total magnetization

2024-02-22 Thread Guido Fratesi
Dear Abdul, the starting magnetization is here defined as (N_UP-N_DW)/(N_UP+N_DW) so a value of 1 means fully polarized, N_UP=N and N_DW=0. Eg if you want 3muB for an atom having 8 electrons you need to put a value of 3/8. To obtain the various minima you may have to sample various initial

[QE-users] pw.x - choosing starting_magnetization value for specific expected total magnetization

2024-02-21 Thread Abdul Muhaymin via users
Hello QE users, As I understood that thestarting_magnetization is used to break the spin symmetry and can affect the solution. When I did a simple calculation changing starting_magnetization, it always converged to the same ground state. However, I noticed that for other structures, this is