Hi,
We recently investigated a similar issue and have a clear understanding on what
this comes from.
Commands sent by PC to usrp device are responded with an acknowledge. Each
command has a sequence number and is sent asynchronously. On the receiving side
there is a check on acknowledge
On 07/12/2018 06:21 PM, Ayaz Mahmud wrote:
Hello Markus,
Thanks for suggestion. Yes, I have two channels.
I don’t know if I am doing this correct, here what I understood from
your suggestion:
1^st Channel : Vector source (1,0)
2^nd Channel : Vector source (0,1)
So when 1^st channel will
Hello Will
This sounds eerily similar to issues I've had using N200s. I basically
found that working at high rates, using either
STREAM_MODE_NUM_SAMPS_AND_DONE or using starts and stops was completely
unusable. The system would go into an unrecoverable set of timeouts or
overflows. I had to
Hey all,
I have built the latest version of UHD and am trying to load up my X300 but
having major issues.
I have used the image downloader script to get the latest versions of the
FPGA image and the image loader to burn the image successfully. Then when I
run uhd_usrp_probe I get to the DDC
On 07/12/2018 05:28 PM, Ayaz Mahmud via USRP-users wrote:
Hello All,
I am using a USRP sink with 2 input channels on 2 TX/RX ports of B210
for transmitting a file.
Now I want to toggle (or ON/OFF) between these transmission ports. For
example:
Ant-1 : Transmit for 1 msec and stop
Ant-2
Hello All,
I am using a USRP sink with 2 input channels on 2 TX/RX ports of B210 for
transmitting a file.
Now I want to toggle (or ON/OFF) between these transmission ports. For example:
Ant-1 : Transmit for 1 msec and stop
Ant-2 : Transmit for 1 msec and stop
And again Ant-1….(loop until a
While working to get coherent streams working, I ran into an issue using an
x310 with two TwinRX daughterboards.
The issue starts with a series of "ERROR_CODE_OVERFLOW (Out of sequence error)"
errors. In an attempt to recover from that, the rx streamer is thrown out and
recreated. The next
Hey Sebastian,
this has been fixed on master branch
(8f16f05b20efcc9e5371c89585b992b237b43eb3) but not on a current release.
We'll remedy as soon as possible.
In a nutshell, there were product IDs that we didn't know about (but
were still valid) when we wrote the code, so we added the new ones
Hey there,
I have an N310 I'm trying to get up and running with, but I keep getting
the same error when I try to probe it. I'm using the latest version of UHD
3.12 (46ab88b) on my host machine, the latest FPGA image for the N310, as
well as the latest file system SD card image. Running
About a year ago, we embarked on developing a similar application.
The TLDR is we never got to 2x200, but we did get 3x100, which to me is
actually a bit better cuz 2x200 is really only 2x160 with the analog filtering,
yet you have all those extra samples you have to take in for no benefit.
It
I think I sent this from the wrong account previously...
About a year ago, we embarked on developing a similar application.
The TLDR is we never got to 2x200, but we did get 3x100, which to me is
actually a bit better cuz 2x200 is really only 2x160 with the analog filtering,
yet you have all
Dear all:
This might be a common problem to many of you but I can’t solve it on my own.
The machine is Dell desktop acquired in recent year, OS is uBuntu 14.04.04 ith
XCHI enabled kernel.
The USRP B210 is literally attached to the USB 3.0 port with a proper cable,
but was immediately
I have the same problem, any help? ^^
2017-06-06 13:45 GMT+02:00 Barker, Douglas W. via USRP-users <
usrp-users@lists.ettus.com>:
> Hello,
>
>
>
> Is there any update on our issue?
>
>
>
> Thanks
>
> Doug
>
>
>
> *From:* Jonathon Pendlum [mailto:jonathon.pend...@ettus.com]
> *Sent:* Monday, May
13 matches