Re: [USRP-users] X310 calibration with WBX

2018-07-03 Thread Nick Foster via USRP-users
OK, just one more bump -- can anyone from Ettus confirm that they're able to get calibration working on X310, and that it actually reduces DC offset and IQ imbalance images? I think it's broken in master as well. Nick On Fri, Jun 29, 2018 at 1:34 PM Nick Foster wrote: > Following up on this, I

Re: [USRP-users] X310 calibration with WBX

2018-06-29 Thread Nick Foster via USRP-users
Following up on this, I have an additional question: is there any plan to expose the DC offset and IQ balance API through device3? Currently it appears as though the legacy interface can make use of these functions to manually set IQ balance and DC offset, while device3-based programs (i.e.,

[USRP-users] X310 calibration with WBX

2018-06-28 Thread Nick Foster via USRP-users
Hi all, I haven't looked at daughterboard calibration in a long time, and picking it up, it sure looks broken to me. I'm using X310 + WBX on rfnoc-devel as of March. Let's assume for the moment I'm running a stock FPGA image -- I'm not, but for testing I replicated the same results on the stock