[Veritas-bu] Client List in Backup, Archive and Restore Window

2008-11-25 Thread Neeraj Puri (DHL MY)
Dear Admins, I have a master server running 6.0 MP4. This master server is in cluster. On connecting to it using the Windows Java Console, If I go into Backup, Archive and Restore window, I don't see the client list in Source client for restore and Destination client for restore.

[Veritas-bu] Error 200

2008-11-25 Thread BlueChris69
Hi, For 2 weeks running i have had 1 policy which hasn't run a weekly full backup. It submits the parent job but sits there looking for a stream but eventually fails with a 200 schedule found no backups due to run. I have checked the policy and first thing is that the daily incrementals and

Re: [Veritas-bu] Error 200

2008-11-25 Thread WEAVER, Simon (external)
http://seer.entsupport.symantec.com/docs/280133.htm Any help? Simon -Original Message- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On Behalf Of BlueChris69 Sent: Tuesday, November 25, 2008 11:56 AM To: VERITAS-BU@mailman.eng.auburn.edu Subject: [Veritas-bu] Error 200 Hi, For 2

Re: [Veritas-bu] Error 200

2008-11-25 Thread Spearman, David
Chris, Are all the schedules in that policy set to calendar? Schedules within a policy either need to be all calendar based (or not) David Spearman County of henrico -Original Message- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On Behalf Of BlueChris69 Sent: Tuesday, November 25,

Re: [Veritas-bu] Client List in Backup, Archive and Restore Window

2008-11-25 Thread ckstehman
Check your auth.conf file to see if your login has jbp=ALL set.. -- Carl Stehman Distributed Services Pepcoholdings, Inc. 701 Ninth St NW Washington DC 20068 202-331-6619 Neeraj Puri (DHL MY) [EMAIL PROTECTED] Sent by:

Re: [Veritas-bu] Client List in Backup, Archive and Restore Window

2008-11-25 Thread judy_hinchcliffe
The client name has to be added. In my experience - the xwindows console on the master will have all the clients But if you are using the windows console on a server other then the master, you have to add the name. ( the button that says edit) I have been using the windows console for

[Veritas-bu] Error 200

2008-11-25 Thread BlueChris69
Thanks for your replies... All of our policies are setup the same, i.e. the weekly and monthly backups are calendar based and the daily incrementals are frequency. This has never caused a problem before. Also, reading that tech note, all of our policies are set the same...so the weekly

Re: [Veritas-bu] Error 200

2008-11-25 Thread WEAVER, Simon (external)
Happy to be proven wrong, is it worth creating a new policy for this, in case there is something that has become corrupt within the existing policy? Its just an after thought really. Sorry the doc wasnt much help Simon -Original Message- From: [EMAIL PROTECTED] [mailto:[EMAIL

Re: [Veritas-bu] how to duplicate the tape

2008-11-25 Thread Rusty . Major
Our answer is either Go read the manual or at least check the help included with the command. You have to at least TRY to do some of the work... Rusty Major, MCSE, BCFP, VCS ▪ Sr. Storage Engineer ▪ SunGard Availability Services ▪ 757 N. Eldridge Suite 200, Houston TX 77079 ▪ 281-584-4693

[Veritas-bu] Puredisk Replication Errors

2008-11-25 Thread mdglazerman
We use Puredisk to back up file servers at our remote sites. We then replicate that backed up data to a duplicate puredisk server at our DR site. The backups to the Puredisk server in our data center work great but some of the replication jobs sending the data to the DR site fail on occasion

[Veritas-bu] 6.5.3 experience

2008-11-25 Thread Dominik . X . Pietrzykowski
Hi all, Ive found that the new 6.5.3 patch seems to make the GUI more hungry for memory and slower than the 6.5.2 version. Anybody else see this ? regards, Dominik This e-mail is sent by or on behalf of the named sender identified above. If: (a) you do not wish to receive any e-mail

[Veritas-bu] bperror command

2008-11-25 Thread judy_hinchcliffe
bperror -U -problems -hoursago 24 this is the bperror command I currently have. but this shows errors for restores as well as backups. does anybody know the trick to get to only show errors for backups. I tried the -t backstat but that gives me restore errors as well.

Re: [Veritas-bu] bperror command

2008-11-25 Thread JCrowe
Dear Judy, I think if you add -t BACKUP to it, so that it would read: bperror -U -problems -t BACKUP -hoursago 24 should do it ... Cheers John John Crowe, Network Engineer 1314 Hay Street West Perth Western Australia 6005 T: +61 8 9488 9440 F: +61 8 9488 9400 M: 0414 637 670

Re: [Veritas-bu] bperror command

2008-11-25 Thread judy_hinchcliffe
Thanks I missed seeing that in the man pages. From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] Sent: Tuesday, November 25, 2008 5:01 PM To: VERITAS-BU@mailman.eng.auburn.edu Cc: Judy Hinchcliffe Subject: Re: [Veritas-bu] bperror command Dear Judy,

[Veritas-bu] Moving to new master

2008-11-25 Thread venkatesh111
Hi All, we are planing to move our netbackup master server to newely built Windows 2003 box old master windows - 2000 veritas version : 5.0MP3 last time we tried this and when trying to configure storage devices none of the tape drives were detected for master (all the drives are visible

Re: [Veritas-bu] Error 200

2008-11-25 Thread bob944
All of our policies are setup the same, i.e. the weekly and monthly backups are calendar based and the daily incrementals are frequency. This has never caused a problem before. Of course, I wouldn't let the fact that Veritas has put this statement Note: A policy can contain more than one

Re: [Veritas-bu] Moving to new master

2008-11-25 Thread WEAVER, Simon (external)
Sounds like some sort of inconsistency. Not sure what your plan is to move to a new master - Are you using bprecover to restore everything back to the new platform? Ideally, it's be better to restore everything to the new hardware, using the same OS/NetBackup revisions from the previous master.

Re: [Veritas-bu] Moving to new master

2008-11-25 Thread Anders Thome
You could on the old master: do one catalogbackup, then delete all the devices, and do second catalogbackup(to disk. And use the last catalogbackup for recovery on the new master.. and then set up devices like it should be. I've done this successfully on an numerous sites. Not from W2000 to