You don't need HDLOs for Cs.
This is more critical for 4f (5f) systems and maybe for elements with
d-states, but not for sp-elements.
Used -lnvs 6 or 8 though !
On 06/19/2018 04:02 AM, Dr. K. C. Bhamu wrote:
Thanks Gavin,
I see, when I use -lnvs x (x=4 to 10 in the interval of 1) the
Thanks Gavin,
I see, when I use -lnvs x (x=4 to 10 in the interval of 1) the
HDLO/lvns warning does not disappear.
When I reduce rmt of Cs from 2.5 to 2.3 these warning goes but then this
small rmt will cost computational time.
As per UG, I see how to add HDLO.
below is my case.int file for
For LVNS, see section "5.1.3 Job control for initialization (init_lapw)"
on page 63 in the WIEN2k 17.1 usersguide [
http://susi.theochem.tuwien.ac.at/reg_user/textbooks/usersguide.pdf ].
There it looks like you just need to add the '-lvns L' switch to your
init_lapw command.
For example, if
Dear Wien2k Users,
For elements with high "Z", we frequently get below warnings:
atom 1 has a large sphere , consider setting HDLOs and/or larger LVNS
I am wondering if someone knows how to set these values in batch mode.
Kind regards
Bhamu
___
4 matches
Mail list logo