Levi Wilson wrote:
In addition to the first message, I can't say for sure that I know
WHICH Merge module is causing the problem, since I tried including it
by itself and it worked. Also, it's just weird that my other product
that uses the same merge modules works fine.
On 1/26/07, *Levi Wils
Simon Topley wrote:
I have a few shared compoents that I will add the same guids back to
as the previous version, I'm sure that will kill off a few error
messages in the log file. When I uninstall the previous version after
uninstalling the current version, the current version reg keys are
sti
Ed Abshire wrote:
I have a question concerning how I can get a set of shared files into
2 different locations.
Separate products can install shared files into different directories
but a single product can install them to just one.
--
sig://boB
http://bobs.org
--
John Cole wrote:
Is this a bug in tallow/heat (I’m using tallow) or is it an issue with
the compiler? The xml makes sense, and I’m just using a xls to
transform de-normalize it. It seems like the compiler is at fault for
not creating the registry table entries correctly from seemingly valid
Levi Wilson wrote:
> I know that Windows Installer "doesn't support" the
> SERVICE_KERNEL_DRIVER flag in the ServiceType field of the
> ServiceInstall table, but why would candle return an error
> (CNDL0073)? If it's unsupported, shouldn't it just be a warning?
The WiX philosophy is to make
Ian Couper wrote:
I tried incorporating that into my installer and it works, just too
well. The installer errors every time, even if the condition is not
met. Any ideas on what might be causing this? The code I'm using is as
follows:
Check a verbose log around the AppSearch action; it rec
Alex Lian wrote:
> But that still doesn't address the problem I consistently see when I
> increase the overall MSI size (with multiple cabs of < 2GB size)
> seems to be > 2GB...
>
Have you tried using external cabs? My day job is working with a
multi-gigabyte package but the .msi itself is onl
Rob Hamflett wrote:
> If your installing per-user, make sure it really is. The Windows Installer
> guys put out a video
> about Windows Installer 4.0 for Vista. They recommended always doing a
> per-machine installer.
The typical "everyone/just for me" radio buttons (as from VS setup
proje
John Lalande wrote:
> I have reached a solution that makes everyone here happy. It
> incorporates what you suggest but adds a small detail. I cannot
> display a dialog from the ARP uninstall, but I can display a dialog
> from my custom action that informs the user of what is happening. It
>
We are seeing an access violation in light.exe (filever 2.0.4103.0)
when creating the cab file for the debug target (happens when the cab
file size exceeds 2 GB) -
light.exe : error LGHT0001 : Attempted to read or write protected
memory. This is often an indication that other memory is corrupt.
I have a question concerning how I can get a set of shared files into 2
different locations.
I have 2 features (a service and a setup application) that have 8 files
in common (and will always be common files).
All 8 files need to be in the same directories as their respective
features...so it w
Ahh...whoops...I think I invoked a build at the same time as that
particular error.
But that still doesn't address the problem I consistently see when I
increase the overall MSI size (with multiple cabs of < 2GB size)
seems to be > 2GB...
filenames and paths removed to protect the innocent. =)
M
Swapping in "<>" fixed both issues! Thank you!
Why is it necessary to use that in some cases though when in other
spots I used "<>" without any problem? Shouldn't using the CDATA
wrapper have prevented it from being an issue?
On 1/30/07, Albert van Peppen <[EMAIL PROTECTED]> wrote:
> Did you try
The 128 characters are the "magic character" the CustomAcitons use to marshal
strings through. You should see valid data in between the magical characters.
-Original Message-
From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On Behalf Of Graham Martin
Sent: Tuesday, January 30, 2007 12:1
0x80070020 is SHARING_VIOLATION. Do you have a virus scanner watching the
built files? That's the way this happens most often. Virus scanners are
notorious for locking up compressed files. I always exempt the build drives
from our virus scanners.
-Original Message-
From: [EMAIL PROT
I tried incorporating that into my installer and it works, just too
well. The installer errors every time, even if the condition is not met.
Any ideas on what might be causing this? The code I'm using is as
follows:
Thanks for your suggestion Duan.
I've tried making the changes you suggested but I'm still not having any
luck creating the database. The log is showing a bit more and I'm now
getting:
"MSI (s) (88:E0) [19:41:10:218]: Invoking remote custom action. DLL:
C:\WINDOWS\Installer\MSI8E.tmp, Entry
Hello,
Is there any way I can control the collation of the database
when the DB is created via SqlDatabase. No attribute on SqlDatabase element
seems to take this in account. Thank you.
Regards,
Marius
--
It's the way that OLE Structured Storage files work. The way to shrink an MSI
back to its smallest size is to dump it to IDT files and reimportant them. If
you look, that's the way the WiX toolset works.
I have to ask though, "Why do you need to modify the MSI after the fact? What
can't WiX
I'm not exceeding any of those statements.
All files are *individually* < 2GB, and I'm setting up multiple cabs
such that none exceed 2GB. I'll double check my wxs file, but I'm pretty
sure I tried to verify that.
I got this error when I did exceed that:
light.exe : fatal error LGHT0017 : Failed
QtExec waits for the program to return. You don't want to use that. Use's
Bob's ShellExecute solution instead.
From: Kaushik Barat [mailto:[EMAIL PROTECTED]
Sent: Tuesday, January 30, 2007 11:54 AM
To: Rob Mensching
Cc: wix-users@lists.sourceforge.net
Subject: Re: [WiX-users] Start application
Hi,
Thanks for the reply.
I tried starting the app after InstallFinalize. The application starts but
the msi installation just hangs in there forever
The CustomAction is defined as follows
These are the lines i use to start the app.
Any idea why the msi hangs around even after the instal
After an installer for our product is built, it may undergo a transformation
by a utility that we wrote...i.e. some properties are changed, Binary table
entries updated, and SummaryInformation updated. This tool uses the
installer COM API.
After this operation, the installer inexplicably grows f
I have reached a solution that makes everyone here happy. It incorporates
what you suggest but adds a small detail. I cannot display a dialog from
the ARP uninstall, but I can display a dialog from my custom action that
informs the user of what is happening. It offers two buttons: Retry and
Exi
Is this a bug in tallow/heat (I’m using tallow) or is it an issue with the
compiler? The xml makes sense, and I’m just using a xls to transform
de-normalize it. It seems like the compiler is at fault for not creating
the registry table entries correctly from seemingly valid xml.
John
_
I'll see if I can contribute by working out what the problem is.
Neil
From: Rob Mensching [mailto:[EMAIL PROTECTED]
Sent: 30 January 2007 17:41
To: Neil Sleightholm; wix-users@lists.sourceforge.net
Subject: RE: Re: [WiX-users] WiX3 Error: The primary key xxx is
duplicated in table 'Registr
There is a bug open on WiX v3 about not quite integrating correctly with
DIFxApp.
From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On Behalf Of Levi Wilson
Sent: Tuesday, January 30, 2007 5:27 AM
To: Quinton Tormanen
Cc: wix-users@lists.sourceforge.net
Subject: Re: [WiX-users] Kernel Drivers
Al
This bug in heat has been reported a couple times. Unfortunately, people just
keep working around the bug instead of helping make a fix for it. So, it
hasn't been fixed because no one is currently maintaining heat.exe.
From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On Behalf Of Neil Sleigh
The FileSize column in the File table has a datatype of "DoubleInteger". From
the documentation:
"The DoubleInteger data type is a four-byte integer value. Unless otherwise
restricted, the range of legal values is from -2,147,483,647 to +2,147,483,647."
Also, it is a known issue that cabinet f
Assuming for the sake of argument that Wix uses the IReferenceIdentity
interface, is there actually a mismatch occurring? The point I'm making
here is that it's normal for the 32-bit-only assemblies to go to GAC_32
and the portable ones to GAC_MSIL, depending on how they were built.
Phil Wilson
The programmer in me can't help but wonder if Light is using an int for the
file size, instead of an
unsigned int. The former's top end is just over 2GB, and would explain what
you're seeing. Whether
or not that's the problem, I don't know. It's just what immediately jumped out
at me.
Rob
Ahh...that makes sense (with also additionally experimenting by me
confirming some of that).
So, I'm still experimenting - splitting up the files across cabs/media -
but light.exe
seems to choke on the large MSI it outputs in the temp directory.
I see this error:
light.exe : error LGHT0001 : Fail
If you're intent on installing to a per-user directory, I don't think there's
anything you can do
about this warning.
Rob
Jason Van Eaton wrote:
> Any hints on fixing the remaining warnings?
>
> JVE
>
>
> -Original Message-
> From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On Behal
I've been using WiX version 2 and just used the Driver* attributes. I
put all the files for a given .INF in a single component, which can go
against the general principal of one .dll per component, but someone
recommended that I do that way; either from this mailing list or the
DIFx support team.
Any hints on fixing the remaining warnings?
JVE
-Original Message-
From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On Behalf Of Jason Van Eaton
Sent: Monday, January 29, 2007 12:50 PM
To: wix-users@lists.sourceforge.net
Subject: [WiX-users] Per-User install warnings on files
I have no
Thanks that gave me the clue I was missing. I think the problem is that
the code fragment is followed by:
Which will do some of the same things (but not all). I am fairly sure
this was generated by heat so it could be a bug in heat but I will do
some more investigation.
I know that Windows Installer "doesn't support" the SERVICE_KERNEL_DRIVER
flag in the ServiceType field of the ServiceInstall table, but why would
candle return an error (CNDL0073)? If it's unsupported, shouldn't it just
be a warning? I say this, because if I manually set the type field to be
SE
Alright, I'm trying to give this DIFxApp a shot. I'm using Version 3 of
WiX, and it will not allow me to put DriverXXX attributes in the component.
Nor will it allow me to use the element inside my component. I've
been trying to go through the article found here (
http://msdn2.microsoft.com/en-
Neil,
I had the same issue when using tallow on a .reg file for an ActiveX.exe.
It turned out that tallow was creating nested registry keys, and those don’t
compile.
For example (and this is from memory, so I’m sure it’s not syntactically
correct):
Dear Partner friends,
With the time we come into new year. First of all, let me wish you and
all yours a prosperous 2007!
As you know Integrate Shipping Limited is a China based freight agent
established in 1997, with our own offices located in Shenzhen, Shanghai and
Beijing ded
Dear All,
First of all thanks for the useful Q&A mailing lists that helps me survive
in my Wix adventure. Especially thanks to Phil who respond to one of my
questions. Have been in Wix for a month and half. So far so good.
However life is not always with sunshine and flowers. Here again,
comes a
Anyone?
Rob
Rob Hamflett wrote:
> I posted this in microsoft.public.platformsdk.msi but didn't get a response.
> Hopefully someone here
> can help me.
>
> I've been looking at a web-based installation using msistuff.exe and
> setup.exe from the Platform
> SDK. I've got is all up and runnin
Did you try using <> instead of <> in your condition?
Like:
FOOVAR <> ""
Iso:
FOOVAR <> ""
Regards,
Albert van Peppen
-Oorspronkelijk bericht-
Van: [EMAIL PROTECTED]
[mailto:[EMAIL PROTECTED] Namens Geoff Finger
Verzonden: maandag 29 januari 2007 21:00
Aan: wix-users@lists.sour
43 matches