Thank you,
Bob.
I have checked single package authoring and it seems that for Windows
Vista it's not possible to create an MSI installer with WixUI_Advanced so
the install just for youradio button on 'advanced' tab work. Am i correct?
If it is so, WixUI_Advanced seems a bit confusing to me:
Try the the archives for this list (eg
http://windows-installer-xml-wix-toolset.687559.n2.nabble.com/wix-users-f687560.html
), the wix-devs mailing list and the wix source code.
-Original Message-
From: Xu, Jun [mailto:jun...@ebay.com]
Sent: 04 September 2010 10:44
To: General
Thanks. I will enter a bug. I already built it myself, but it will be better to
use this library from SDK, to always have up-to-date version.
От: Bob Arnson [mailto:b...@joyofsetup.com]
Отправлено: Чт, 02.09.2010 8:34
Кому: wix-users@lists.sourceforge.net
Тема:
http://wix.sourceforge.net/manual-wix3/wixnetfxextension.htm shows also
NETFRAMEWORK40FULL and NETFRAMEWORK40CLIENT
-Original Message-
From: Ian Ceicys [mailto:ian.cei...@noblegroupinternational.com]
Sent: September 6, 2010 16:48
To: General discussion for Windows Installer XML toolset.
Open a bug. This shouldn't be a problem. Be sure to include the full version
of the WiX toolset you are using.
On Tue, Aug 31, 2010 at 2:46 PM, Maillet, Ed email...@unum.com wrote:
Hey all,
I've got a MSI that installs a virtual directory using the
iis:WebVirtualDir element to an existing
If you put the Website inside a Component element, the Component element
controls it's lifetime. This is the same behavior that Files and Registry
Keys have.
You can move the Website out of the Component if you just want it to be a
search.
On Sun, Aug 22, 2010 at 11:17 PM, Sagar
You can modify the dialogs. The WiX.chm has documentation how to do this.
On Thu, Aug 19, 2010 at 2:44 PM, Umesh Joglekar
umesh_jogle...@hotmail.comwrote:
Hi,
Is there a way to customize WIX MessageBoxes?
Thanks
Umesh
I can't say I truly understood the original requirements. The Windows
Installer does generally expect the stuff it installed to be important so it
does things like repair if stuff is missing.
On Wed, Aug 11, 2010 at 8:29 AM, Pally Sandher pally.sand...@iesve.comwrote:
Something is locking the IIS metabase preventing the installer from writing
to it. You can see the retries in there because there can be things that
randomly lock the metabase. But 30 seconds is usually enough unless
something is being rather abusive.
On Wed, Aug 11, 2010 at 9:39 AM, Joseph Vano
Check out heat.exe. That's about the best we have right now...
On Thu, Aug 5, 2010 at 1:01 AM, Satyaprakash J sat...@smartek21.com wrote:
Hi,
I would like use Wix for deploying a ASP.Net Web
Application. I have added the Wix project to the solution which contains
the ASP.NET
Did you ever root cause this?
On Sat, Jul 31, 2010 at 11:13 PM, Bassam Tabbara bassamtabb...@gmail.comwrote:
Thanks Rob. We did notice this started happening after adding a new managed
custom action. The custom action does not need a rollback so we didn't
schedule one. Does this seem
SHA1 hash of the target path. It took us a long time to come up with it but
we finally got it. You can see the code in wix\src\wix\Binder.cs -
Binder::SetComponentGuids()
On Sun, Sep 5, 2010 at 8:59 AM, Alex Ivanoff alex.ivan...@shavlik.comwrote:
No. * component guids are stable, not randomly
Actually, I don't expect we'll add any more functionality than this. The WiX
IIS CustomActions don't provide 100% coverage of IIS6 and we won't get 100%
of IIS7 either. The surface is big and returns diminish quickly... smile/
On Thu, Sep 2, 2010 at 7:37 PM, John L Krupka john.kru...@nmwco.com
Deferred custom action? What user context is that running under? You might
be surfing the web from an elevated process which seems incredibly
dangerous. smile/
I've been disappointed by embedded UI (random limitations). At this point,
I've focused on building a really solid external UI.
On Tue,
Please file a bug.
On Wed, Sep 1, 2010 at 12:34 AM, Valentijn Makkenze v.makke...@vicrea.nlwrote:
After upgrading wix the output path of one of my wix projects has changed
The locale directory is gone
Output used to be : Debug\nl-nl\
But is now Debug\
More details
Wix build 3.5.2020
It
There were some big fixes to Votive in the last week or so. You might try a
more recent build.
On Tue, Aug 31, 2010 at 6:38 AM, Valentijn Makkenze v.makke...@vicrea.nlwrote:
One or more projects in the solution where not loaded correctly.
Please see the Output Window for details.
It looks like your shortcut directory tree is getting rooted in
ProgramFilesFolder. That typically maps to C:\Program Files. I think you
want your shortcut directory tree to be rooted in Program*Menu*Folder.
On Mon, Aug 30, 2010 at 2:37 AM, Tzvi Tafet tta...@gmail.com wrote:
Hi,
I've would
Yep, very old Windows Installer behavior.
On Mon, Aug 30, 2010 at 6:55 PM, Elfe Xu elf...@microsoft.com wrote:
And in this post
http://windows-installer-xml-wix-toolset.687559.n2.nabble.com/Website-gets-deleted-when-uninstalling-Web-App-td5436443.html
If you keep everything as separate libraries, there shouldn't be any
duplicate symbols. If you are combining .wixlibs, well that way leads to
madness. smile/
It isn't clear from your description below which way you are going.
On Wed, Aug 25, 2010 at 11:35 AM, jhennessey
Strange. We (Microsoft lawyers, actually) picked the CPL because it wasn't
too restrictive. Licenses aren't like software. You can't just upgrade them
because they are old. smile/
I'd like to understand better the root issue here. It is theoretically
possible for WiX to change the license but I'd
Have the C++ code be a Custom Action that sets Properties and then use
Component Conditions?
On Thu, Aug 26, 2010 at 4:30 AM, Mathias Kahl mat...@gmx.de wrote:
Hi,
i want to create a Setup which decides on an output of a c++ application
which files need to be installed. Is there any option to
I like to use the AssertSz(FALSE, debug XxxCA here); from dutil.h. The
resulting dialog gives lots of information to make it easy to attach.
On Wed, Aug 25, 2010 at 2:00 PM, gapearce mr_gapea...@yahoo.com wrote:
I found it pretty easy and straightforward using VS2008 to attach to a
setup
That's a great way.
On Thu, Aug 26, 2010 at 11:29 AM, gapearce mr_gapea...@yahoo.com wrote:
I should add that I'm using this mechanism now, and I test
OLDERVERSIONBEINGUPGRADED, but I wanted to ask if this is the right way,
or is there a different property I can also test?
Upgrade
SourceDir can be a bit troublesome on repair/uninstall. Be careful:
http://robmensching.com/blog/posts/2010/1/26/StackOverflow-what-does-NameSourceDir-refer-to
On Mon, Aug 23, 2010 at 2:04 PM, Andy Glass agl...@laserfiche.com wrote:
Sounds like a bug. Please provide a verbose log file with the repro steps.
On Mon, Aug 30, 2010 at 5:34 PM, saikodi saik...@hotmail.com wrote:
Hello,
I offer two features one of which is a web site component. In order to
avoid
triggering of the ConfigureIIS CA when the non-web component is
What is a shared directory? A file share? If so, no the Windows Installer
doesn't install to file shares because it wants to manage the installed
application. A file share is typically removable and thus not something you
manage an application through... typically.
On Mon, Aug 23, 2010 at 12:25
What does the verbose log file say?
On Fri, Aug 20, 2010 at 6:44 AM, James Green james.gr...@lalpac.com wrote:
Hi All,
I've just followed this example
http://wix.sourceforge.net/manual-wix3/create_start_menu_shortcut.htm to
the
letter in my own script but still no short cut. Do I need
Try a more recent build. There have been a lot of fixes in IIS7
functionality.
On Wed, Aug 18, 2010 at 7:06 PM, Igor Lemsky igor.lem...@gmail.com wrote:
I simply install IIS Virtual directory and independent IIS Application pool
for this Directory. As I understand my IIS Application Pool must
ARPSIZE Property?
On Tue, Aug 17, 2010 at 4:42 PM, Elfe Xu elf...@microsoft.com wrote:
Hi,
In my product MSI, I reserve cost for the data folder with 200M, because
later when the application running, it's likely that the application will
write lots of data to the disk.
Directory
You can't log or, IIRC, launch other dialogs from a custom action activated
by a DoAction. MSI limitation.
On Tue, Aug 17, 2010 at 12:16 PM, Umesh Joglekar umesh_jogle...@hotmail.com
wrote:
Hi,
I have a custom action executable written in c++. This pops up the browser
to the appropriate
Hmm, does this blog entry help:
http://robmensching.com/blog/posts/2007/4/27/How-to-create-an-uninstall-shortcut-and-pass-all-the
On Tue, Aug 10, 2010 at 4:35 PM, Vijai Kalyanapasupathy
vkal...@microsoft.com wrote:
I have looked around all day for solutions to this issue, but I couldn't
find
This might be interesting as well:
http://robmensching.com/blog/posts/2010/1/26/StackOverflow-what-does-NameSourceDir-refer-to
On Thu, Aug 5, 2010 at 12:25 PM, Blair os...@live.com wrote:
The Source attribute of the File element currently ignores the SourceDir\
beginning when it finds it.
Hi Bob,
I've added that attribute, but it didn't change the behavior.
I ended up doing a workaround where I set a new property in the UI sequence
that it then gets persisted to the InstallExecuteSequence
I can send you the repro if you need it.
Date: Thu, 2 Sep 2010 09:01:48 -0400
From:
I have a few more questions. We have a 32-bit installer today with all
component ids explicitly specified. We are planning to move to 32/64 bit
installer (mutualy exclusive) with the ability to upgrade current
installations (major upgrade).
1. Should we update explicit component ids to *?
2. What
Verbose log file will probably tell the most.
On Sat, Aug 7, 2010 at 7:47 PM, Lucius Fleuchaus luci...@microsoft.comwrote:
The shared library uses the File element without the KeyPath attribute.
File Id=CommonLibraryAssembly DiskId=1 Name=Common.dll
Source=$(var.TARGETDIR)\Common.dll/
My hypothesis is that you have a [#fileid] in the registry key that does not
exist.
On Mon, Aug 9, 2010 at 11:05 AM, Wang, Miaohsi miaohsi.w...@invensys.comwrote:
Hello,
We are getting two ICE errors when building the msi:
light.exe(0,0): error LGHT0204: ICE03: Not a valid foreign key;
Yeah, heat on websites doesn't quite work, yet. Maybe in WiX v4.0
On Tue, Aug 3, 2010 at 7:43 AM, Satyaprakash J sat...@smartek21.com wrote:
Hi,
I am using the command heat website RunwayUI -template product -out
website.wxs to create a .wxs file. But I get a null reference exception.
Could
If you schedule your RemoveExistingProducts early, that removes the previous
version of the product before installing the new one. Essentially that gives
you a clean slate to rev all of your Component GUIDs.
Pretty much all the other options mean you have to be very careful about
managing your
We schedule RemoveExistingProducts after InstallValidate, so it should be
safe to change all component ids.
Are there any issues upgrading 63-bit to 64-bit (as far as Windows Installer
is concerned)?
On Mon, Sep 6, 2010 at 23:34, Rob Mensching r...@robmensching.com wrote:
If you schedule your
39 matches
Mail list logo