Re: [WiX-users] WiX 3.8 MakeSfxCA.exe exited with code 3

2014-09-16 Thread Robert Harrison
I probably should add details about my previous question. I'm using WiX 3.8 on my local dev machine running Win 8.2 and everything is building fine. Our build machines were apparently using Win XP and this bug reared its head today when we upgraded our build machines to Win 7. What changed in th

Re: [WiX-users] WiX 3.8 MakeSfxCA.exe exited with code 3

2014-09-16 Thread Robert Harrison
Does anyone know why this workaround is only needed on Win 7? -Original Message- From: John H Bergman (XPedient) [mailto:john.berg...@xpdnt.com] Sent: Tuesday, September 16, 2014 5:31 PM To: General discussion about the WiX toolset. Subject: Re: [WiX-users] WiX 3.8 MakeSfxCA.exe exited wi

Re: [WiX-users] WiX 3.8 MakeSfxCA.exe exited with code 3

2014-09-16 Thread John H Bergman (XPedient)
I've used the workaround with success. -Original Message- From: Robert Harrison [mailto:robert.harri...@citrix.com] Sent: Tuesday, September 16, 2014 6:55 PM To: General discussion about the WiX toolset. Subject: Re: [WiX-users] WiX 3.8 MakeSfxCA.exe exited with code 3 After some more di

Re: [WiX-users] WiX 3.8 MakeSfxCA.exe exited with code 3

2014-09-16 Thread Robert Harrison
After some more digging, I found this post (http://wixtoolset.org/issues/4277/) about a bug in Wix 3.8. I'm not allowed to make this change due to our distributed build system, but can someone confirm that this workaround is correct? -Robert -Original Message- From: Robert Harrison [ma

[WiX-users] WiX 3.8 MakeSfxCA.exe exited with code 3

2014-09-16 Thread Robert Harrison
Wix Users, My project will not building due to the following error. I have searched to find answer but found nothing satisfactory. What I did find was that code 3 is a "file not found" code. Is that correct? Anyone seen this before? T:\Wix\v3.8.1128.0\sdk\Wix.CA.targets(141,5): error MSB3073:

Re: [WiX-users] Installing VSTO as pre-requisites from Bundle.wxs Failed

2014-09-16 Thread Liz
The VSTO redist package you downloaded via the fwlink is failing signature verification because it was updated last week, which most likely no longer matches with the vstor_redist.exe you used to compile your bootstrapper. Updating the redist source file to the latest version should resolve this i

Re: [WiX-users] WIX : Upgrade Issue

2014-09-16 Thread Phil Wilson
It's also not readily obvious (at least to me) that the upgrade path is actually being taken. It looks like it might be failing and rolling back quite early. It's probably worth doing a sanity check that the upgrade logic is correct and it's going down that path. If it went into maintenance mode th

Re: [WiX-users] Getting the lenght of string in Edit/MaskedEdit field

2014-09-16 Thread Dave Andersen
It sounds like you will need a custom action. I'm pretty sure there is no built-in way of getting a variable string length. -Dave On Fri, Sep 12, 2014 at 10:58 AM, TimM wrote: > I have a MaskedEdit control that can either be blank or filled in. If blank > then next button will continue, but if

Re: [WiX-users] WIX : Upgrade Issue

2014-09-16 Thread Rob Mensching
That should not happen with DTF. _ Short replies here. Complete answers over there: http://www.firegiant.com/ -Original Message- From: Phil Wilson [mailto:phildgwil...@gmail.com] Sent: Tuesday, September 16, 2014 10:56 AM To:

Re: [WiX-users] LGHT0284: Support for more than 260 characthers in Path?

2014-09-16 Thread Asbjørn Mikkelsen
ah, that worked fine like this: c b1 b2 b3 On Tue, Sep 16, 2014 at 7:45 PM, Rob Mensching wrote: > Ahh, I was probably looking at WiX v4.0 targets. > > At least you can control the prefix in WiX v3.x targets. > _ > Sh

Re: [WiX-users] WIX : Upgrade Issue

2014-09-16 Thread Phil Wilson
Regarding the "wrong custom action" issue: there have been problems in that area with managed custom actions where the uninstall part of the upgrade runs first, loading the assembly for that older custom action. When the new install runs and the loading code comes to load the new assembly the runti

Re: [WiX-users] LGHT0284: Support for more than 260 characthers in Path?

2014-09-16 Thread Rob Mensching
Ahh, I was probably looking at WiX v4.0 targets. At least you can control the prefix in WiX v3.x targets. _ Short replies here. Complete answers over there: http://www.firegiant.com/ -Original Message- From: Asbjørn Mikkelsen [

Re: [WiX-users] LGHT0284: Support for more than 260 characthers in Path?

2014-09-16 Thread Asbjørn Mikkelsen
In the wix2010.targets I found CleanFile defined, so I could remap one file, but further on I found this: So those seems to be built on the fly, instead of getting assigned to an property as is done with CleanFile.. Same wi

Re: [WiX-users] Intermittent errors setting Windows 8 properties on shortcuts

2014-09-16 Thread John Hall
Rob, I am using the GUID - it appears in the error message. I've got a define called var.Prop_System_AppUserModel_NoPin that I use. Regards, John -Original Message- From: Rob Mensching [mailto:r...@firegiant.com] Sent: 16 September 2014 16:59 To: General discussion about the WiX toolse

Re: [WiX-users] LGHT0284: Support for more than 260 characthers in Path?

2014-09-16 Thread Asbjørn Mikkelsen
Hm, I added those in the same propertygroup as where OutputPath and IntermediateOutputPath is set, but nothing happens, it generates stil the same names Where are those properties listed?, like what is avalable? In this doc: http://wixtoolset.org/documentation/manual/v3/overview/light.html I cant

Re: [WiX-users] LGHT0284: Support for more than 260 characthers in Path?

2014-09-16 Thread Rob Mensching
PS: I just remembered, you can change the name of those files in your .wixpproj by setting Properties like BindContentsFile, BindOutputsFile, etc. _ Short replies here. Complete answers over there: http://www.firegiant.com/ -Origi

Re: [WiX-users] Intermittent errors setting Windows 8 properties on shortcuts

2014-09-16 Thread Rob Mensching
Know Windows Installer issue. Use the GUID of the property instead of the name. _ Short replies here. Complete answers over there: http://www.firegiant.com/ -Original Message- From: John Hall [mailto:john.h...@cambridgetechgrou

Re: [WiX-users] WIX : Upgrade Issue

2014-09-16 Thread ArvindJanghel
Hi John, Thanks for the reply.The upgrade used to work well previously..Also i am sure, that the changes that was done later on, does not break the upgrade. I already have your suggested approach #2 implemented when the major upgrade was implemented. I have a custom action which takes a backup o

Re: [WiX-users] WIX : Upgrade Issue

2014-09-16 Thread John Cooper
If no modifications to the config files have been made since they have been installed, they will be deleted with your upgrade scheduling before the upgrade install. You can: 1) tweak the timestamp on the config file(s) so they are preserved; or 2) have a custom action read the file data to be

[WiX-users] WIX : Upgrade Issue

2014-09-16 Thread Arvind Janghel
Hi, I have implemented major upgrade support in my application installer . As part of upgrade, there are C# custom actions to backup and restore config files, and also update the database. I have scheduled the RemoveExistingProducts after "installinitialize". However the restore configurat

[WiX-users] Intermittent errors setting Windows 8 properties on shortcuts

2014-09-16 Thread John Hall
Hi, In my installer I have a number of shortcuts installed on the Start Menu that I don't want to appear on the Windows 8 start screen. I therefore set both the System.AppUserModel.StartPinOption and System.AppUserModel.ExcludeFromShowInNewInstall properties for each of these shortcuts. My cod

Re: [WiX-users] Bundle that upgrades two different bundles (different upgrade codes)

2014-09-16 Thread Stabiplan Development
To answer my own question: this appears to work. The DetectRelatedBundle event gives only product codes. Is there a way to find the advertises name (from ARP) that belongs to a bundle product code? Met vriendelijke groet, Rob van Rosmalen B ICT software engineer stabiplan +31 172 65 02 65 w

Re: [WiX-users] Check that at least one Feature is selected

2014-09-16 Thread Noel Farrugia
So there isn't a simpler solution? All I want to do is have access to a "variable", in this case myFeature from another file. > Date: Mon, 15 Sep 2014 09:21:00 -0400 > From: yellowjacketl...@gmail.com > To: wix-users@lists.sourceforge.net > Subject: Re: [WiX-users] Check that at least one Feat