I am still somewhat new, but I thought the value of a Publish tag was a
condition. I am not sure what a condition of "5000" would mean. Condition "1"
is always true and that publish would always fire. The value of the property is
set by the @Value attribute.
John Harvey
-Original Message-
Have you looked at the version numbers on the files? This sort of a shot in the
dark, but I believe MSI will not install a file with an older version number.
John Harvey
-Original Message-
From: Blair [mailto:os...@live.com]
Sent: Monday, February 22, 2010 4:30 PM
To: 'General discussio
The first place to look is the publish events on the dialog's Next button.
Maybe something is getting called that isn't doing anything or calling the same
dialog. If you can post the XML for the dialog here, folks may see something
you don't.
John Harvey
-Original Message-
From: Rober
RemoveFile does work and it is allowed. Why is this? Is there something
RemoveFile is doing that I can emulate? Or is there a way to have RemoveFolder
work with a non-empty folder?
John Harvey
-Original Message-
From: Harvey, John Ctr USAF Warfighter's Edge
[mailto:joh
the impersonation setting for the custom action?
And there is a RemoveFile element in WiX that will do this kind of thing
without you writing code.
Phil Wilson
-Original Message-
From: Harvey, John Ctr USAF Warfighter's Edge
[mailto:john.har...@wedge.hpc.mil]
Sent: Friday, Febr
d line, it works. However, I can't find a way to use Run As for
the control panel or Programs and Features.
Any suggestions?
John Harvey
Developer, Warfighter's Edge (WEdge)
HQ USAFA/DFEI
2354 Fairchild Drive, Suite 4H43
USAF Academy, CO 80840-1344
(719) 333-0626
john.
On uninstall, can you remove registry keys from all the various users HKU
hives? Or will it remove from the current user only?
John Harvey
--
Download Intel® Parallel Studio Eval
Try the new software tools for yourself. S
I have been using Session.Log to send messages to the log. However, my results
seem inconsistent. Sometimes messages make it to the log and some don't. Even
within the same custom action. Is there something going on with the log that I
need to be aware of? Does it optimize out useless messages o
NVM... I had a subtle error in my custom action. Apparently I need to broadcast
my stupidity before I can see it.
-Original Message-
From: Harvey, John Ctr USAF Warfighter's Edge
[mailto:john.har...@wedge.hpc.mil]
Sent: Tuesday, February 16, 2010 8:21 AM
To: General discussio
Sorry, I forgot to specify. The property is TIER1LIST. I separated out the line
that has the delete below.
-Original Message-
From: Harvey, John Ctr USAF Warfighter's Edge
[mailto:john.har...@wedge.hpc.mil]
Sent: Tuesday, February 16, 2010 8:12 AM
To: General discussion for Wi
This one has me stumped.
I have a dialog. The dialog has a combo box. The list of the combo box is
populated in a custom action. When running the install, the list on the combo
box has nothing. When looking in the log, I can see where the list is getting
populated and also there is a line when
Feb 11, 2010 at 10:12 AM, Harvey, John Ctr USAF Warfighter's Edge
wrote:
> I have a property
>
> Secure="yes" Value="NOT SET"/>
>
> Which is set at the top of my WXS file. In the InstallExecuteSequence I
> change it insid
I have a property
Which is set at the top of my WXS file. In the InstallExecuteSequence I change
it inside a custom action. Just to see the new value, I put the property in a
Text in the Exit dialog.
The value shows the original value 'NOT SET
We have shortcuts installed that trigger a repair if something missing is
detected. Is there some way to find out what triggered the repair? I have logs,
but I don't know what to look for.
--John Harvey
--
The Planet: d
I would put the source files in unmanaged components (no GUID on the component)
and then remove them through a custom action after the compile. You may need
placeholder files that represent the compiled binaries so they get removed on
uninstall.
John Harvey
-Original Message-
From: sea
Books is shadi Bartsch Thomas Erotikon is Essays
Eros Modern am Chicago Chicago Press helen a Fisher why. Books is shadi Bartsch
Thomas Erotikon is Essays Eros Modern am Chicago Chicago Press helen a Fisher
why.
Erotikon Essays in Eros Modern Chicago
Chicago Press helen Fisher why or Love o
16 matches
Mail list logo