" , "wsjt-devel"
, "Black Michael"
Verzonden: Dinsdag 29 augustus 2023 20:39:32
Onderwerp: Re: [wsjt-devel] Problem with Hamlib
Hi Rudy,
Ensure you use DATA-USB mode at your Yaesu FT-991 ( not USB). Important are
also the following menu settings at yo
*Van: *"DG2YCB Uwe"
*Aan: *"on4ckt"
*Verzonden: *Dinsdag 29 augustus 2023 11:35:15
*Onderwerp: *Re: [wsjt-devel] Problem with Hamlib
Really strange. Or is perhaps com0com breaking the connection? What
happens if you temporarily disable com0c
gustus 2023 11:35:15
Onderwerp: Re: [wsjt-devel] Problem with Hamlib
Really strange. Or is perhaps com0com breaking the connection? What happens if
you temporarily disable com0com and use COM3 only for WSJT-X?
But in case FreeDV supports OmniRig, I would really recommend you OmniRig 1.20.
G2YCB sent me. I may find a solution there.
I'll keep you informed.
Thanks in advance.
ON4CKT Rudy
- Oorspronkelijk bericht -
Van: "Black Michael via wsjt-devel"
Aan: "on4ckt--- via wsjt-devel"
Cc: "Black Michael"
Verzonden: Maandag 28 augustus
Hi Uwe,
I have used the same serial port for CAT (no PTT) and DTR or RTS for PTT with
my FT1000MP, but of course you can’t have at the same time a hardware flow
control.
73 Reino OH3mA
I use CAT. If you have DTR or RTS selected, make sure the COM port for that is
different from the CAT se
I may find a solution there.
I'll keep you informed.
Thanks in advance.
ON4CKT Rudy
- Oorspronkelijk bericht -
Van: "Black Michael via wsjt-devel"
Aan: "on4ckt--- via wsjt-devel"
Cc: "Black Michael"
Verzonden: Maandag 28 augustus 2023 23:08:50
Onderwe
That makes it sound like it's the wrong port.
You should have two COM ports -- the Extended port is the one you want.
Mike W9MDB
On Monday, August 28, 2023 at 10:07:56 AM CDT, on4ckt--- via wsjt-devel
wrote:
Hello, today I tried to install WSJT-X v2.7.0-rc2 on my laptop Windows10
Hello Rudy,
Your settings for the FT-991 seem to be fine. I have the same settings
here (and 028=RS232C), and everything works well. How is your PTT
connected? I use CAT. If you have DTR or RTS selected, make sure the COM
port for that is different from the CAT serial port. Is COM3 the right
one?