Hi,
 
 I've resolved my problem yourself and I write for those interested.
 Multiple model mode doesn't switch in HYP interactive mode.
 The user schould answer the question 'Interactive operation' - 'N'.
 I can not find this condition in Seisan manual, I think it should be there.
 
 Best regards
 Grażyna
 
> Od: [email protected]
> Do: [email protected]; 
> Wysłane: 14:11 Środa 2013-06-12
> Temat: HYP multiple model mode
> 
> > 
> > Hi everyone,
> > 
> > has anyone used the function HYP in multiple model mode to determine 
> > crustal structure?
> > I've tried without the expected result.
> > According to manual, HYP will switch to multiple mode when the input 
> > parameter file h_models.par is in the working directory and the input must 
> > be from a single file.
> > Instead of h_models.out with some models and RMS, I've got hyp.out, 
> > print.out and hypsum.out with hypocenter calculated with crustal model in 
> > station0.hyp.
> > 
> > Does enyone know what is missing?
> > Is there any example of this HYP option?
> > 
> > Thank you in advance for your tips
> > 
> > Grazyna
> > 
> > 
> > 
> 
> 
> 
> 




_______________________________________________
seisan mailing list
[email protected]
http://mailman.uib.no/listinfo/seisan