Hi, I've resolved my problem yourself and I write for those interested. Multiple model mode doesn't switch in HYP interactive mode. The user schould answer the question 'Interactive operation' - 'N'. I can not find this condition in Seisan manual, I think it should be there. Best regards Grażyna > Od: [email protected] > Do: [email protected]; > Wysłane: 14:11 Środa 2013-06-12 > Temat: HYP multiple model mode > > > > > Hi everyone, > > > > has anyone used the function HYP in multiple model mode to determine > > crustal structure? > > I've tried without the expected result. > > According to manual, HYP will switch to multiple mode when the input > > parameter file h_models.par is in the working directory and the input must > > be from a single file. > > Instead of h_models.out with some models and RMS, I've got hyp.out, > > print.out and hypsum.out with hypocenter calculated with crustal model in > > station0.hyp. > > > > Does enyone know what is missing? > > Is there any example of this HYP option? > > > > Thank you in advance for your tips > > > > Grazyna > > > > > > > > > >
_______________________________________________ seisan mailing list [email protected] http://mailman.uib.no/listinfo/seisan