Gra?yna
Fine you soleved it, I will add a comment to the manual
jens
On Thu, 13 Jun 2013, [email protected] wrote:
Hi,
I've resolved my problem yourself and I write for those interested.
Multiple model mode doesn't switch in HYP interactive mode.
The user schould answer the question 'Interactive operation' - 'N'.
I can not find this condition in Seisan manual, I think it should be there.
Best regards
Gra?yna
Od: [email protected]
Do: [email protected];
Wys?ane: 14:11 ?roda 2013-06-12
Temat: HYP multiple model mode
>
> Hi everyone,
>
> has anyone used the function HYP in multiple model mode to determine crustal structure?
> I've tried without the expected result.
> According to manual, HYP will switch to multiple mode when the input
parameter file h_models.par is in the working directory and the input must be from
a single file.
> Instead of h_models.out with some models and RMS, I've got hyp.out, print.out
and hypsum.out with hypocenter calculated with crustal model in station0.hyp.
>
> Does enyone know what is missing?
> Is there any example of this HYP option?
>
> Thank you in advance for your tips
>
> Grazyna
>
>
>
_______________________________________________
seisan mailing list
[email protected]
http://mailman.uib.no/listinfo/seisan
_______________________________________________
seisan mailing list
[email protected]
http://mailman.uib.no/listinfo/seisan