Of course--  The BSL programming script requires SW control of MSP430
reset, TCK, BSL TX and BSL RX.

The USB Reader dock has an SMSC260x flash reader + hub.  Hanging off
one of the downstream SMSC USB ports is an FT2232 dual USB UART.  One
port is tied to above 4 lines, the other is connected to the MSP430
USART UART lines.
The reset line is specifically connected to ADBUS4 on the FTDI (DTR#).

-Ben

> Are you saying that it is possible to reset the shimmer via the FTDI
> driver? I did not known about this. Which chipset is in the dock?
>
> Best,
> Miklos
>
>>
>> I recommend that windows users evaluate this update.
>>
>> -Ben
>> _______________________________________________
>> Shimmer-users mailing list
>> [email protected]
>> https://lists.eecs.harvard.edu/mailman/listinfo/shimmer-users
>>
>
_______________________________________________
Shimmer-users mailing list
[email protected]
https://lists.eecs.harvard.edu/mailman/listinfo/shimmer-users