Dear SIESTA users,


I am using SIESTA on the HPCx (www.hpcx.ac.uk), running on 32 processors
and with a 200 atom system (MgO surface).

One way to set the ON.eta parameter for the order-N method is to ask
SIESTA to calculate the electronic chemical potential
(ON.ChemicalPotentialUse .true.) that will further be used instead of
ON.eta for the order-N energy functional minimization.
This works well with serial SIESTA running on one of our locoal linux
machines, but on HPCx, I get the following error:

"MPI was not finalized in string, task number" and the calculation stops
immediately, before being able to get the electronic chemical potential.
I can run an order-N job without this option, by specifying ON.eta by hand.

I know this kind of error means that an MPI program exited without
calling MPI_finalize.
Does anybody know how to deal with it?


Thank you for your help,

Rudy Coquet.
Cardiff University
UK