Hi Carlos, Thanks a lot for the reply. Nobody answered my question and I really 
didn't know what should I do.I progressed well and don't want to switch to 
another software due to this simple problem..
I've enabled all the options you mentioned in my input.fdf (I copy it in the 
following) file.I had a look into my directory where I ran previous TranSiesta 
job. When I list *.TSDE I find "scat.TSDE" file,but when I list *.TSHS I can't 
find such file except for the one I already put there as the input for 
previousTranSiesta file (it is called "elec.TSHS"). 
Another point is that when I run the continuation job, inside the produced 
OUTPUT.fdf file it is written "Continuation run".But as soon as the section 
"transiesta: TSiscf" is printed out, it starts from number 1 while the previous 
runstops at number 63 and I expect the continuation run start from 64 and not 
63..
Can you guess what is wrong? 
All the Best and thanks again for your time,Zeynab
P.S.INPUT.fdf file :**********************************SystemName    scat        
                                                                                
                             SystemLabel   scat
%block kgrid_Monkhorst_Pack  1  0   0    0.0  0   1   0    0.0  0   0   5   
0.0%endblock kgrid_Monkhorst_Pack

xc.functional           GGA                     xc.authors              PBE     
                
MeshCutoff              1000.00000000 Ry SolutionMethod  Transiesta             
          OccupationFunction      MP                      ElectronicTemperature 
  300 K                   
SpinPolarized           F                       FixSpin                 F       
                
MaxSCFIterations        1000                               DM.NumberPulay       
   6                     DM.NumberBroyden        0                       
DM.MixingWeight         0.05          DM.OccupancyTolerance   0.1000000000E-11  
      DM.NumberKick           0                       DM.KickMixingWeight     
0.5000000000            DM.Tolerance            1.000000000E-04UseSaveData      
       T                                         MD.NumCGsteps        0         
           MD.TypeOfRun            CG                       MD.VariableCell     
  F                      MD.MaxCGDispl           0.2000000000  Bohr       
MD.MaxForceTol          0.05 eV/Ang              #MD.MaxStressTol         
0.0001 eV/Ang**3        MD.UseSaveXV      .true.MD.UseSaveCG  TDM.UseSaveDM     
     true   
Diag.ParallelOverK      F                                                
PAO.EnergyShift         50 meV                    PAO.SplitNorm           
0.1500000000              PAO.BasisType           split                     
PAO.BasisSize           DZP                                WriteMullikenPop     
           0WriteBands                      FSaveRho                         
.true.SaveDeltaRho                    .true.SaveHS                          
.true.SaveElectrostaticPotential      .true. SaveTotalPotential              
yesWriteCoorXmol                   .true.WriteMDXmol                     
.true.WriteMDhistory                  .false.WriteEigenvalues                
yesWriteDM                  T
                                                                                
                                             %include POSITIONS.fdf

# Transiesta informationSolutionMethod Transiesta # GENGF 
OPTIONSTS.ComplexContour.Emin        -24 eV TS.ComplexContour.NPoles       
16TS.ComplexContour.NCircle      16TS.ComplexContour.NLine        10 # BIAS 
OPTIONSTS.biasContour.NumPoints       10

# TS OPTIONSTS.Voltage 0.00  eV
# TBT OPTIONSTS.TBT.Emin -3 eVTS.TBT.Emax +3 eVTS.TBT.NPoints 500TS.TBT.NEigen 
3TS.TBT.Eta        0.000001 Ry
# Write electrode hamiltonianTS.SaveHS   .true.TS.SaveLead .true.
TS.MixH                 TTS.UpdateDMCROnly       TSCFMustConverge         T
# LEFT ELECTRODETS.HSFileLeft  ./elec.TSHS TS.NumUsedAtomsLeft   
12TS.BufferAtomsLeft    0
# RIGHT ELECTRODETS.HSFileRight  ./elec.TSHS TS.NumUsedAtomsRight  
12TS.BufferAtomsRight   0
DM.UseSaveDM    T



====================================================================================================
 

    On Saturday, July 2, 2016 11:24 AM, Carlos Sanz <[email protected]> wrote:
 

  
 Dear Zeynab,
 
 as in any SIESTA run, you will have to set up the typical restarting 
parameters in the fdf file such as
 
 DM.UseSaveDM  .true.   (during a TranSIESTA run, the .DM values are used for 
the density matrix in the buffer (if used)            
                                          and electrode regions)
 
 DM.UseSaveXV   .true.
 
 etc... In addition, and what really makes a specific TranSIESTA restarting, 
you must check that you have the *.TSHS and *.TSDE files from the previous run 
in the directory where you are going to restart TranSIESTA. By the way, 
TS.SaveHS is true by default, so you should find the *.TSHS from the previous 
run unless you set  up TS.SaveHS false previously.
 
 - The *.TSHS file contains the information (e.g.: Hamiltonian matrix once self 
consistency is achieved and overlap matrix) necessary for the scattering region 
calculation. If both electrodes are identical structures, the same .*.TSHS can 
be used to describe both. In general, however, the electrodes can be different 
and therefore you will have two different *.TSHS files; one for the left 
electrode and and another for the right electrode. 
 
 - The *.TSDE file contains the density matrix for the TranSIESTA calculations. 
It is equivalent to the *.DM file for SIESTA (i.e., density matrix with 
periodic boundary conditions in all directions and no voltage), but the density 
and energy matrix stored in *.TSDE has open boundary conditions and bias 
potential. 
 
 best regards,
 
 SIMUNE support team
 
 El 02/07/16 a las 07:08, zeynab mohamad hoseyni escribió:
  
         Dear all,  
  I would really appreciate if someone kindly answer to my question:
 How I can restart a TranSiesta job from the previous run? Is there any option 
 that I have to enable in the .fdf file so that continuing a job from previous 
job which has been stopped due to lack of wall-time?
 
 Would be so much thankful to help me on that.
 
 All the Best,
 Zeynab
  
          
 
 -- 
 SIMUNE Atomistic Simulations#yiv1882498632 body{font-family:Arial, Helvetica, 
sans-serif;font-size:11px;color:#4D4D4D;line-height:18px;}#yiv1882498632 
.yiv1882498632horia{color:#E7731F!important;font-size:13px!important;font-weight:bold;line-height:20px;}#yiv1882498632
 
.yiv1882498632titulo{font-weight:bold!important;font-size:13px!important;}#yiv1882498632
 td{font-size:12px;}#yiv1882498632 .yiv1882498632borde-arriba{}#yiv1882498632 
.yiv1882498632borde-abajo{}#yiv1882498632 
a{cursor:pointer;color:#4a4a4a!important;text-decoration:none!important;}#yiv1882498632
 a:hover{text-decoration:underline!important;}#yiv1882498632 img{border:none;}
|  Support
 Simune Atomistics
  Tolosa Hiribidea 76 | 20018 Donostia - San Sebastián | Spain 
 T.: +34 943 57 40 42 | [email protected] | www.simune.eu   |   |

 

  

Responder a