Hi Nick!
Thanks a lot for your attention.. So much happy.. ;-)
All the Best,Zeynab 

    On Sunday, July 3, 2016 10:14 AM, Nick Papior <[email protected]> wrote:
 

 Hi  zeynab, 
See comments in line. --Kind regards Nick Papior
On 3 Jul 2016 10:13, "zeynab mohamad hoseyni" <[email protected]> wrote:
>
> Hi Carlos,
>  
> Thanks a lot for the reply. Nobody answered my question and I really didn't 
> know what should I do.
> I progressed well and don't want to switch to another software due to this 
> simple problem..
>
> I've enabled all the options you mentioned in my input.fdf (I copy it in the 
> following) file.
> I had a look into my directory where I ran previous TranSiesta job. When I 
> list *.TSDE I find "scat.TSDE" file,
> but when I list *.TSHS I can't find such file except for the one I already 
> put there as the input for previous
> TranSiesta file (it is called "elec.TSHS"). 
In fact, TSHS file isn't used for a continuation run. 
>
> Another point is that when I run the continuation job, inside the produced 
> OUTPUT.fdf file it is written "Continuation run".
> But as soon as the section "transiesta: TSiscf" is printed out, it starts 
> from number 1 while the previous run
> stops at number 63 and I expect the continuation run start from 64 and not 
> 63..
A continuation run does not know what the previous runs Scf count is, so it 
starts over. 
If it says it has read in the TSDE file, then it is a continuation run. 
>
> Can you guess what is wrong? 
So I would guess nothing is wrong and it actually behaves as expected. :) 
>
> All the Best and thanks again for your time,
> Zeynab
>
> P.S.
> INPUT.fdf file :
> **********************************
> SystemName    scat                                                            
>                                                          
> SystemLabel   scat
>
> %block kgrid_Monkhorst_Pack
>   1  0   0    0.0
>   0   1   0    0.0
>   0   0   5   0.0
> %endblock kgrid_Monkhorst_Pack
>
>
> xc.functional           GGA                     
> xc.authors              PBE                     
>
> MeshCutoff              1000.00000000 Ry 
> SolutionMethod  Transiesta                       
> OccupationFunction      MP                      
> ElectronicTemperature   300 K                   
>
> SpinPolarized           F                       
> FixSpin                 F                       
>
> MaxSCFIterations        1000                    
>            
> DM.NumberPulay          6                     
> DM.NumberBroyden        0                       
> DM.MixingWeight         0.05          
> DM.OccupancyTolerance   0.1000000000E-11        
> DM.NumberKick           0                       
> DM.KickMixingWeight     0.5000000000            
> DM.Tolerance            1.000000000E-04
> UseSaveData             T                       
>                   
> MD.NumCGsteps        0                    
> MD.TypeOfRun            CG                       
> MD.VariableCell       F                      
> MD.MaxCGDispl           0.2000000000  Bohr       
> MD.MaxForceTol          0.05 eV/Ang              
> #MD.MaxStressTol         0.0001 eV/Ang**3        
> MD.UseSaveXV      .true.
> MD.UseSaveCG  T
> DM.UseSaveDM          true   
>
> Diag.ParallelOverK      F                                                
> PAO.EnergyShift         50 meV                    
> PAO.SplitNorm           0.1500000000              
> PAO.BasisType           split                     
> PAO.BasisSize           DZP          
>                       
> WriteMullikenPop                0
> WriteBands                      F
> SaveRho                         .true.
> SaveDeltaRho                    .true.
> SaveHS                          .true.
> SaveElectrostaticPotential      .true. 
> SaveTotalPotential              yes
> WriteCoorXmol                   .true.
> WriteMDXmol                     .true.
> WriteMDhistory                  .false.
> WriteEigenvalues                yes
> WriteDM                 T
>
>                                                                               
>                                                
> %include POSITIONS.fdf
>
>
> # Transiesta information
> SolutionMethod Transiesta 
> # GENGF OPTIONS
> TS.ComplexContour.Emin        -24 eV 
> TS.ComplexContour.NPoles       16
> TS.ComplexContour.NCircle      16
> TS.ComplexContour.NLine        10 
> # BIAS OPTIONS
> TS.biasContour.NumPoints       10
>
>
> # TS OPTIONS
> TS.Voltage 0.00  eV
>
> # TBT OPTIONS
> TS.TBT.Emin -3 eV
> TS.TBT.Emax +3 eV
> TS.TBT.NPoints 500
> TS.TBT.NEigen 3
> TS.TBT.Eta        0.000001 Ry
>
> # Write electrode hamiltonian
> TS.SaveHS   .true.
> TS.SaveLead .true.
>
> TS.MixH                 T
> TS.UpdateDMCROnly       T
> SCFMustConverge         T
>
> # LEFT ELECTRODE
> TS.HSFileLeft  ./elec.TSHS 
> TS.NumUsedAtomsLeft   12
> TS.BufferAtomsLeft    0
>
> # RIGHT ELECTRODE
> TS.HSFileRight  ./elec.TSHS 
> TS.NumUsedAtomsRight  12
> TS.BufferAtomsRight   0
>
> DM.UseSaveDM    T
>
>
>
>
> ==================================================
> ==================================================
>
>
> On Saturday, July 2, 2016 11:24 AM, Carlos Sanz <[email protected]> wrote:
>
>
>
> Dear Zeynab,
>
> as in any SIESTA run, you will have to set up the typical restarting 
> parameters in the fdf file such as
>
> DM.UseSaveDM  .true.   (during a TranSIESTA run, the .DM values are used for 
> the density matrix in the buffer (if used)            
>                                          and electrode regions)
>
> DM.UseSaveXV   .true.
>
> etc... In addition, and what really makes a specific TranSIESTA restarting, 
> you must check that you have the *.TSHS and *.TSDE files from the previous 
> run in the directory where you are going to restart TranSIESTA. By the way, 
> TS.SaveHS is true by default, so you should find the *.TSHS from the previous 
> run unless you set up TS.SaveHS false previously.
>
> - The *.TSHS file contains the information (e.g.: Hamiltonian matrix once 
> self consistency is achieved and overlap matrix) necessary for the scattering 
> region calculation. If both electrodes are identical structures, the same 
> .*.TSHS can be used to describe both. In general, however, the electrodes can 
> be different and therefore you will have two different *.TSHS files; one for 
> the left electrode and and another for the right electrode. 
>
> - The *.TSDE file contains the density matrix for the TranSIESTA 
> calculations. It is equivalent to the *.DM file for SIESTA (i.e., density 
> matrix with periodic boundary conditions in all directions and no voltage), 
> but the density and energy matrix stored in *.TSDE has open boundary 
> conditions and bias potential. 
>
> best regards,
>
> SIMUNE support team
>
> El 02/07/16 a las 07:08, zeynab mohamad hoseyni escribió:
>>
>> Dear all, 
>>
>> I would really appreciate if someone kindly answer to my question:
>> How I can restart a TranSiesta job from the previous run? Is there any 
>> option 
>> that I have to enable in the .fdf file so that continuing a job from 
>> previous job
>> which has been stopped due to lack of wall-time?
>>
>> Would be so much thankful to help me on that.
>>
>> All the Best,
>> Zeynab
>>
>
> -- 
> Support
> Simune Atomistics
> Tolosa Hiribidea 76 | 20018 Donostia - San Sebastián | Spain 
> T.: +34 943 57 40 42 | [email protected] | www.simune.eu
>
>


  