On 07/15/2016 10:19 PM, Paul Fertser wrote:
> There're two essential modifications in this change:
>
> 1. Fix timing for capture frequencies less than 200 kHz;
> 2. Sample ADC output after CLK is set low, as per the TLC5510
> datasheet.
>
> The second point is also important as the capture state sets CLK low,
> so with the previous code there might have been a very short glitch on
> this line during capture. Not confirmed by measurements, but it's
> cleaner this way.
>
> Signed-off-by: Paul Fertser <fercer...@gmail.com>
> ---


LGTM

Care to implement analog mux relay switching also ?

/Benjamin



------------------------------------------------------------------------------