On 07/15/2016 10:19 PM, Paul Fertser wrote: > There're two essential modifications in this change: > > 1. Fix timing for capture frequencies less than 200 kHz; > 2. Sample ADC output after CLK is set low, as per the TLC5510 > datasheet. > > The second point is also important as the capture state sets CLK low, > so with the previous code there might have been a very short glitch on > this line during capture. Not confirmed by measurements, but it's > cleaner this way. > > Signed-off-by: Paul Fertser <fercer...@gmail.com> > ---
LGTM Care to implement analog mux relay switching also ? /Benjamin ------------------------------------------------------------------------------ What NetFlow Analyzer can do for you? Monitors network bandwidth and traffic patterns at an interface-level. Reveals which users, apps, and protocols are consuming the most bandwidth. Provides multi-vendor support for NetFlow, J-Flow, sFlow and other flows. Make informed decisions using capacity planning reports.http://sdm.link/zohodev2dev _______________________________________________ sigrok-devel mailing list sigrok-devel@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/sigrok-devel