Ode,
Thanks for all of the information on Bob Beck's interview
Mary--------------------------------------------
On Mon, 10/13/14, Ode Coyote <[email protected]> wrote:

 Subject: Re: CS>sodium bicarbonate or sodium carbonate?
 To: [email protected]
 Date: Monday, October 13, 2014, 7:03 AM
 
 
     All generators that use electricity and water make the
 OH[-] anions
     in a one to one ratio to the Ag[+] ions.
 
     OH[-] rich water is known as [true]  "Alkaline
 Water"
 
     
 
     Using a  buffer such as Baking Soda will produce Silver
 Carbonate
     which is a photo-reactive compound [as is Silver
 Chloride made when
     using salt]
 
     
 
     The only way to make EIS faster is to use bigger
 electrodes to
     spread the current out....or more voltage, but that
 tends to
     overload the Nernst Diffusion layer resulting in high
 silver
     hydroxide and silver oxide content [ yellow-brown-black
 CS].
 
     
 
     Ode
 
     
 
     On 10/13/2014 9:32 AM,
 Top Dog wrote:
 
     
     
       
         
           Not sure if no one has an opinion on this or
 if it got
             lost when the site went down.  Curious on this
 and doesn't
             seem to be enough info I can find that swings
 the benefits
             or lack of one way or the other.  Also since I
 haven't yet
             purchased a machine this helps as well.  I
 think I've
             narrowed down to one that has reasonable times
 for creation
             and can make larger batches or be able to make
 larger
             batches just because it doesn't take 8hrs to
 create a
             smaller batch.
 
              
 
           
           Thanks,
 
           
 
         
         -Bob
 
       
       
 
         On Thu, Oct 9,
 2014 at 10:35 AM, Top
           Dog <[email protected]>
           wrote:
 
           
             
               
                 
                   
                     I've come across 2
 manufacturers that are
                       advocating the use of sodium
 bicarbonate(baking
                       powder) cspro system and then sodium
 carbonate for
                       the Silvertron Elite model.
 
                       
 
                     
                     Does anyone have any real experience
 doing this as
                     everything I have read so far says not
 to use
                     anything other than Distilled water?  I
 know they
                     are doing it to increase conductivity
 and say there
                     is no reaction but I am still curious on
 what if any
                     changes this really makes to the Ionic
 solution.  I
                     also know that this does raise the PH a
 bit which is
                     a benefit.
 
                     
 
                   
                   In the Silver Lungs machine it states that
 the PH is
                   around 10 but they don't use any of
 the carbonates to
                   increase it so I'm also curious on how
 that gets that
                   high without the use of an additive.
 
                   
 
                 
                 Any thought?
 
                 
 
               
               -Bob
 
             
           
         
         
 
       
     
     
 
   
 
 
 
 
 
                        
                                
                        
                
                        
                                This email is free from viruses and malware 
because avast! Antivirus protection
 is active.
                        
                
 
 



--
The Silver List is a moderated forum for discussing Colloidal Silver.
  Rules and Instructions: http://www.silverlist.org

Unsubscribe:
  <mailto:[email protected]?subject=unsubscribe>
Archives:
  http://www.mail-archive.com/[email protected]/maillist.html

Off-Topic discussions: <mailto:[email protected]>
List Owner: Mike Devour <mailto:[email protected]>