I have run a series of experiments with CS H2O2 NaCl and ammonia. Here are the results
1. CS with H2O2 and NaCl & ammonia 1 CS 5 ppm HVAC very slightly yellow CS 5 ppm HVAC - very slight yellow 2 .add NaCl slightly milky H2O2 - clear, no yellow 3. add H2O2 slightly milky NaCl - very slightly milky 4 add ammonia clears instantly ammonia - clears instantly Notes. Adding NaCl to ionic silver will produce Silver Chloride, which forms a white precipitate. Adding H2O2 to ionic silver produces AgO, silver oxide, which dissolves in cold water up to 13 ppm. There are two ways to interpret this, and I am trying to figure out a way to test between them. 1. H2O2 forms AgO, which then will react somewhat with NaCl producing a combination of AgCl and AgO and that an equilibrium will be formed between the two. However I would expect if this were true, both the above would have produced the same amount of milkyness, but they did not. 2. H2O2 reacts with the silver ions giving AgO which reacts again and forms Ag + O2 releasing oxygen, and then forms AgO again, thus giving a mixture of both silver atoms and Silver Oxide and liberating oxygen. Adding the salt only reacted with the silver oxide, not the atoms. However, I would have expected the H2O2 to continue reacting with the silver atoms that were left, producing silver oxide, which would then produce silver chloride and increasing the milkyness of the solution over time. The milkyness did not seem to increase over time, so this is possibility is also suspect. Experiment #2. Placed clean silver wire into H2O2. Initially bubbles formed, then after a few hours the water started turning milky. The wire remained silver colored until the water turned milky, then the wire started turning a light brown (tan) color, like the color of the cathode when making EIS. This would have to be either silver oxide or silver peroxide. Since silver oxide is either brown or black and silver peroxide is either gray or black, this was most likely silver oxide. The milky water when at the same visual density as the waters above, was indistinguishable by eye from either of the milky silver suspensions above. I added ammonia to the milky water, and it immediately cleared, meaning that this is not a valid test to determine the presence of silver chloride since it also works on silver oxide. I took the wire which had a tan colored residue on it and put it in boiling water, and the residue immediately dissolved off. This proves it was silver oxide since silver peroxide is totally insoluble in water at any temperature. So thus far this is what the experiments have indicated. 1. Adding H2O2 will instantly form silver oxide with any silver ions. This will dissolve leaving the solution clear, up to some ppm. If the ppm of this solution is over that amount (13 ppm?), then a light brown precipitate will form, giving the solution a milky color. If additional H2O2 is added beyond what is necessary to react with all the ions, then the metallic metal will begin forming silver oxide. This will reduce the particle size (making yellow CS clear and reducing Tyndall) and the entire batch will become clear, unless more than that certain amount of silver is in the water (13 ppm), in which case it will turn slightly milky with silver oxide precipitate. 2. Taking the cathode of an EIS setup which has silver oxide on it (although silver hydroxide is initially formed on this electrode, it spontaneously loses a hydrogen atom and becomes silver oxide) and putting it into H2O2 will initially result in the silver oxide dissolving into the H2O2 (which is 97% water), and cleaning it. However the surface of the silver will react with the liberated mono atomic oxygen liberated, and will produce additional silver oxide until the H2O2 solution saturates, in which case the solution starts turning milky, and the silver oxide coating will return to the electrode. 3. The black coating on the anode of an EIS electrode is silver peroxide AgO2. This is totally insoluble in water. I do not have any silver peroxide coated silver to experiment with, but if I read the messages right, bubbles form when this electrode is placed in the water, and the black flakes off effectively cleaning the electrode. This is probably due to the silver it is adhering to forming silver oxide, which then dissolves out from under it so it loses it's adhesion. Then after the H2O2 saturates with silver oxide, it begins forming a layer of silver oxide on the electrode. This is easy to demonstrate by placing this in boiling water for a couple of minutes and it will dissolve off. The next experiment I plan to run will be how silver oxide reacts with glucose. I do not have any pure glucose at this time, but plan on getting some as soon as I can. According to some sources, silver oxide and glucose will react producing metallic silver, and oxidizing the glucose. If this is true then that would mean that silver oxide should immediately be reduced to a colloidal silver in the blood stream when it encounters glucose. I am not sure if the particles would be one atom, 12 atoms or something else. Also, it is apparent that when silver oxide is added to a fluid that has chlorine atoms, that part of it reacts with the chlorine producing some silver chloride, so some of the silver oxide will still become silver chloride when it enters the stomach.. Anyway, it appears that putting some H2O2 into EIS will enhance the amount of silver that makes it into the blood stream. If one were to add some glucose at the same time as the H2O2 is added this might even increase it more, preventing any from forming AgCl by producing atomic silver colloid. But I still have some experiments to do to prove or disprove that. Note that silver oxide is photo sensitive. So it appears that on the face of it, drinking EIS that has been partially or completely converted to silver oxide could cause argyria. This may be so, but if the silver oxide converts to silver particles rapidly enough when it contacts glucose, then that should prevent it from reaching the skin in that form. Also if the EIS that had H2O2 added to it still had a significant portion of it that was still colloid, then that also would help prevent the silver oxide from causing argyria via the development effect. At any rate, it seems apparent that if one wants to add H2O2 it is important to either add the right amount, or consume it immediately after adding it, before all the silver particles form silver oxide. Still got experiments to run, but this is starting to make some sense now. Marshall -- The Silver List is a moderated forum for discussing Colloidal Silver. Instructions for unsubscribing are posted at: http://silverlist.org To post, address your message to: [email protected] Silver List archive: http://escribe.com/health/thesilverlist/index.html Address Off-Topic messages to: [email protected] OT Archive: http://escribe.com/health/silverofftopiclist/index.html List maintainer: Mike Devour <[email protected]>