On 5 January 2016 at 00:25, Mark Pizzolato <m...@infocomm.com> wrote: > Thanks for the image and config. > You're quite welcome.
> I don't see the " XM4: is missing ECO's, but will still function." > Messages... Can you explain? > There's only one DMR11 and one DMC11 configured. When you boot up, you'll see: sim> b rq XM1: is missing ECO's, but will still function. RSTS V10.1-L RSTS (DU0) INIT V10.1-0L Both of the devices are ATTACHed. So the DMR11 doesn't error, the DMC11 (DMC1 to SIMH; XM1 to RSTS/E) still shows the ECO message. I'm still running git commit ca4a6901; I have not applied Paul Koning's patch yet. Comment out the "attach DMCn" lines in the config and you'll get both errors: sim> b rq Device XM0: internal micro-diagnostic failure - device disabled. XM1: is missing ECO's, but will still function. RSTS V10.1-L RSTS (DU0) INIT V10.1-0L Regards, Christian -- Christian M. Gauger-Cosgrove STCKON08DS0 Contact information available upon request. _______________________________________________ Simh mailing list Simh@trailing-edge.com http://mailman.trailing-edge.com/mailman/listinfo/simh