Hi Dave,
I have been involved in a project using VAX-2780-3780PE and have been able to 
connect two VAX’s together using a Black Box Synchronous Modem Eliminator ( SME 
).
Product code: ME204A-F. 
No VAX PSI involved.
Needed Decnet Plus and Wan drivers.

Was able to test using a utility that comes with the Protocol Emulator - XJTEST 
which can use either VAX as a loopback.
In my case it was a DSV11 to a DSW42 using the SME and the V.24 cables that 
come with the adapters.
There is also another utility called REMOTE that can transfer simple files from 
VAX to VAX.
I don’t think there is a driver for SIMH that can emulate a sync device. ( yet 
).

Regards,
John Welsh.

Sent from my  iPhone

> On 20 Mar 2020, at 03:38, dave porter <dave_list_a...@verizon.net> wrote:
> 
> I know almost nothing about VAX PSI, but I have a vague idea
> that even though X.25 is asymmetric and intended for DTE to DCE communication 
> (i.e., your computer to the phone company's premises), it may be possible to 
> coerce it
> into talking from one VAX to another (via null modem
> cable connecting two devices such as DUP-11s).
> 
> I worked on RSX-11M PSI and that's how we tested in
> the lab.  I can no longer remember how that was done.
> Undocumented option somewhere, no doubt.
> 
> 
> _______________________________________________
> Simh mailing list
> Simh@trailing-edge.com
> http://mailman.trailing-edge.com/mailman/listinfo/simh

_______________________________________________
Simh mailing list
Simh@trailing-edge.com
http://mailman.trailing-edge.com/mailman/listinfo/simh

Reply via email to