Hi,
In Sec 15.1.1:
The UAC MUST consider the session terminated as soon as
the BYE request is passed to the client transaction.
If the response for the BYE is a 481 or a 408 or no response at all
is received for the BYE ,
the UAC MUST consider the session and the dialog terminated.
So when will a UAC terminate a session and/or a dialog?
Shall it wait for the 200 from the UAS?