On Thu, 2008-09-25 at 10:40 -0700, IT Services wrote: > Hey there: > > I am configuring 3.10.2 with PSTN lines. I'm testing two gateways: > > Linksys 3102 > Grandstream 4108 > > Both gateways were virtually plug-and-play with respect to receiving > external calls and placing outbound calls. No problems there (except for > low volume, but that's a different issue). > > But when I configure an internal extension to call forward to an > external number (e.g., a cell number), the Linksys 3102 works but the > Grandstream 4108 does not work. I get the standard '...your call did not > go through, please check the number and dial again.' > > I don't know a lot about what data is sent to the gateways, but > obviously, the linksys is processing it correctly, while the grandstream > is not. Does anyone have any hints on where to start troubleshooting?
To know for sure, you'll have to do a proper call trace of a failed call. But a few hours later today, someone reported that Grandstream gateways are buggy in that they use the To URI to make the outgoing call, rather than the request-URI. And a forwarded call always has the To URI different from the request-URI; the To URI is the number originally called and the request-URI is the number to which the call was forwarded. Dale _______________________________________________ sipx-users mailing list sipx-users@list.sipfoundry.org List Archive: http://list.sipfoundry.org/archive/sipx-users Unsubscribe: http://list.sipfoundry.org/mailman/listinfo/sipx-users