5th plus the master?  Because that would make 6.  Max is 5.

Mike

On Tue, Aug 14, 2012 at 12:37 AM, Martin Rodriguez <gmartin...@gmail.com>wrote:

> Hi:
>
> I have problem add more Sip Proxy. I'm adding a fifth secondary proxy and
> fail data replication. Seeking information and encounter problems in older
> versions, did not update the file /etc/sipxpbx/registrar-config, in this
> file there is a parameter SIP_REGISTRAR_SYNC_WITH. The new server isn't
> in the list.
>
> Apply the changes after the system begins to fail and lose the records.My 
> version is sipXecs
> (4.4.0- 2012-07-09EDT12:40:36 ip-10-72-43-110).
>
> Any have idea?
>
> Thanks
> Martin
>
>
>
> _______________________________________________
> sipx-users mailing list
> sipx-users@list.sipfoundry.org
> List Archive: http://list.sipfoundry.org/archive/sipx-users/
>



-- 
Michael Picher, Director of Technical Services
eZuce, Inc.

300 Brickstone Square****

Suite 201****

Andover, MA. 01810
O.978-296-1005 X2015
M.207-956-0262
@mpicher <http://twitter.com/mpicher>
linkedin <http://www.linkedin.com/profile/view?id=35504760&trk=tab_pro>
www.ezuce.com

------------------------------------------------------------------------------------------------------------
There are 10 kinds of people in the world, those who understand binary and
those who don't.
_______________________________________________
sipx-users mailing list
sipx-users@list.sipfoundry.org
List Archive: http://list.sipfoundry.org/archive/sipx-users/

Reply via email to