Hi, try ... Nodes=awn-[001-032,046-077,095-099,100-199] ...
but haven't tested that right now. Best, Herbert Am 26.09.23 um 13:22 schrieb Felix:
hello I have at my site the following work nodes awn001 ... awn099 and then it continues awn100 ... awn199 How can I configure this linePartitionName=debug Nodes=awn-0[01-32,46-77,95-99] Default=YES MaxTime=INFINITE State=UPso that it can contain the nodes from 001 to 199 can I write:PartitionName=debug Nodes=awn-0[01-32,46-77,95-99] awn-1[00-99] Default=YES MaxTime=INFINITE State=UPis this correct? Thank you Felix
-- Herbert Steininger Universität Konstanz Kommunikations-, Informations-, Medienzentrum (KIM) Wissenschaftliches Rechnen | bwHPC 78457 Konstanz Tel: +49 7531 882103