I've been trying to use Tranzeo TR-CPE with SB AP's. The TR-CPE's lock up consistently. I've been told by Tranzeo that it's a SB issue with the following explanation:
The issue appears to be in the Sleep Mode of the AP, or rather the lack of a sleep mode handling routine. Prism and Agere chipsets send wakeup frames to clients, and Atmels do not unless the firmware has code added. The TR-CPE has been told that it is disassociated, but the SB thinks it is still associated. THe TR-CPE sends reassociation beacons, which the SB ignores because it thinks the radio is still associated. I SB hasn't made any comment other than "Were looking into it" and that was on 8-27. Good luck, Mike -----Original Message----- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] Behalf Of Mickey Sent: Thursday, September 04, 2003 10:27 AM To: [EMAIL PROTECTED] Subject: [smartBridges] SB/Tranzeo Anyone using Tranzeo and SB together? do they play well together? do they (Tranzeo) work well ingeneral? Thanks, Mickey ----------ANNOUNCEMENT---------- Don't forget to register for WISPCON IV http://www.wispcon.info/us/wispcon-iv/wispcon-iv.htm The PART-15.ORG smartBridges Discussion List To Join: mailto:[EMAIL PROTECTED] (in the body type subscribe smartBridges <yournickname> To Remove: mailto:[EMAIL PROTECTED] (in the body type unsubscribe smartBridges) Archives: http://archives.part-15.org ----------ANNOUNCEMENT---------- Don't forget to register for WISPCON IV http://www.wispcon.info/us/wispcon-iv/wispcon-iv.htm The PART-15.ORG smartBridges Discussion List To Join: mailto:[EMAIL PROTECTED] (in the body type subscribe smartBridges <yournickname> To Remove: mailto:[EMAIL PROTECTED] (in the body type unsubscribe smartBridges) Archives: http://archives.part-15.org