found on smartmontools-support.
smartctl version 5.1-14 Copyright (C) 2002-3 Bruce Allen
Home page is http://smartmontools.sourceforge.net/

=== START OF INFORMATION SECTION ===
Device Model:     TOSHIBA MK1016GAP
Serial Number:    90722144T
Firmware Version: U1.11 A
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   5
ATA Standard is:  Exact ATA specification draft version not indicated
Local Time is:    Fri Jun 20 17:46:40 2003 /etc/localtime
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

Error SMART Status command via HDIO_DRIVE_TASK failed: Input/output error
Rebuild older linux 2.2 kernels with HDIO_DRIVE_TASK support enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Off-line data collection status: (0x00) Offline data collection activity was
                                        never started.
                                        Auto Off-line Data Collection: 
Disabled.Self-test execution status:      (   0) The previous self-test routine 
completed
                                        without error or no self-test has ever
                                        been run.
Total time to complete off-line
data collection:                 ( 148) seconds.
Offline data collection
capabilities:                    (0x1b) SMART execute Offline immediate.
                                        Automatic timer ON/OFF support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        No Conveyance Self-test supported.
                                        No Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        No General Purpose Logging support.
Short self-test routine
recommended polling time:        (   1) minutes.
Extended self-test routine
recommended polling time:        (  17) minutes.

SMART Attributes Data Structure revision number: 6
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  
WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000b   253   100   050    Pre-fail  Always       
-       0
  2 Throughput_Performance  0x0004   102   100   050    Old_age   Offline      
-       0
  3 Spin_Up_Time            0x0026   100   100   001    Old_age   Always       
-       1599
  4 Start_Stop_Count        0x0032   100   100   000    Old_age   Always       
-       1357
  5 Reallocated_Sector_Ct   0x0033   100   100   001    Pre-fail  Always       
-       1
  8 Seek_Time_Performance   0x0004   100   100   050    Old_age   Offline      
-       0
  9 Power_On_Hours          0x0032   094   094   050    Old_age   Always       
-       2402
 10 Spin_Retry_Count        0x0033   126   100   030    Pre-fail  Always       
-       0
 12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always       
-       1304
199 UDMA_CRC_Error_Count    0x0032   100   100   000    Old_age   Always       
-       0
220 Disk_Shift              0x0002   100   100   001    Old_age   Always       
-       4124
222 Loaded_Hours            0x0032   098   098   050    Old_age   Always       
-       1047
223 Load_Retry_Count        0x0032   100   100   050    Old_age   Always       
-       0
224 Load_Friction           0x0022   100   100   050    Old_age   Always       
-       0
225 Load_Cycle_Count        0x0032   076   076   070    Old_age   Always       
-       242157
226 Load-in_Time            0x0026   100   100   001    Old_age   Always       
-       390
228 Power-off_Retract_Count 0x0032   099   099   060    Old_age   Always       
-       955
240 Head_Flying_Hours       0x0001   100   100   001    Pre-fail  Offline      
-       3

SMART Error Log Version: 1
ATA Error Count: 4
        DCR = Device Control Register
        FR  = Features Register
        SC  = Sector Count Register
        SN  = Sector Number Register
        CL  = Cylinder Low Register
        CH  = Cylinder High Register
        D/H = Device/Head Register
        CR  = Content written to Command Register
        ER  = Error register
        STA = Status register
Timestamp is seconds since the previous disk power-on.
Note: timestamp "wraps" after 2^32 msec = 49.710 days.

Error 4 occurred at disk power-on lifetime: 2411 hours
When the command that caused the error occurred, the device was active or 
idle.
After command completion occurred, registers were:
ER:40 SC:08 SN:87 CL:a2 CH:fb D/H:e0 ST:51
Sequence of commands leading to the command that caused the error were:
DCR   FR   SC   SN   CL   CH   D/H   CR   Timestamp
 00   00   10   7f   a2   fb    e0   c8     35180.793
 00   00   18   77   a2   fb    e0   c8     35139.293
 00   00   18   77   a2   fb    e0   c8     35094.677
 00   00   18   ff   a6   fd    e0   c8     35094.661
 00   00   18   47   cb   fc    e0   c8     35094.253

Error 3 occurred at disk power-on lifetime: 2411 hours
When the command that caused the error occurred, the device was active or 
idle.
After command completion occurred, registers were:
ER:40 SC:08 SN:87 CL:a2 CH:fb D/H:e0 ST:51
Sequence of commands leading to the command that caused the error were:
DCR   FR   SC   SN   CL   CH   D/H   CR   Timestamp
 00   00   18   77   a2   fb    e0   c8     35139.293
 00   00   18   77   a2   fb    e0   c8     35094.677
 00   00   18   ff   a6   fd    e0   c8     35094.661
 00   00   18   47   cb   fc    e0   c8     35094.253
 00   00   08   6d   94   d5    e0   ca     35084.925

Error 2 occurred at disk power-on lifetime: 2411 hours
When the command that caused the error occurred, the device was active or 
idle.
After command completion occurred, registers were:
ER:01 SC:08 SN:87 CL:a2 CH:fb D/H:e0 ST:51
Sequence of commands leading to the command that caused the error were:
DCR   FR   SC   SN   CL   CH   D/H   CR   Timestamp
 00   00   18   77   a2   fb    e0   c8     35094.677
 00   00   18   ff   a6   fd    e0   c8     35094.661
 00   00   18   47   cb   fc    e0   c8     35094.253
 00   00   08   6d   94   d5    e0   ca     35084.925
 00   00   28   87   f6   29    e1   ca     35084.924

Error 1 occurred at disk power-on lifetime: 2411 hours
When the command that caused the error occurred, the device was active or 
idle.
After command completion occurred, registers were:
ER:40 SC:08 SN:b7 CL:a2 CH:fb D/H:e0 ST:51
Sequence of commands leading to the command that caused the error were:
DCR   FR   SC   SN   CL   CH   D/H   CR   Timestamp
 00   00   08   b7   a2   fb    e0   c8     34760.851
 00   00   10   97   a2   fb    e0   c8     34710.840
 00   00   10   47   b1   fb    e0   c8     34710.839
 00   00   08   2f   b1   fb    e0   c8     34710.782
 00   00   08   3f   c6   1a    e1   ca     34710.781

SMART Self-test log, version number 1
Num  Test_Description    Status                  Remaining  
LifeTime(hours)  LBA_of_first_error
# 1  Extended off-line   Completed                     00%      2374         -
# 2  Short off-line      Completed                     00%      2374         -
-------------------------------------------------------------------------
This SF.Net email is sponsored by the Moblin Your Move Developer's challenge
Build the coolest Linux based applications with Moblin SDK & win great prizes
Grand prize is a trip for two to an Open Source event anywhere in the world
http://moblin-contest.org/redirect.php?banner_id=100&url=/
_______________________________________________
Smartmontools-database mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/smartmontools-database

Reply via email to